Does external ultrasound accelerate thrombolysis? Results from a rabbit model.

Author:

Kornowski R1,Meltzer R S1,Chernine A1,Vered Z1,Battler A1

Affiliation:

1. Neufeld Cardiac Research Institute, Chaim Sheba Medical Center, Tel Hashomer, Israel.

Abstract

BACKGROUND Prior in vitro and in vivo studies have reported that external ultrasound accelerates thrombolysis at intensities too low to have a direct effect on clot dissolution in the absence of a thrombolytic agent. The present study was undertaken to examine the ultrasound effect on thrombolysis and reocclusion in a rabbit thrombosis model. METHODS AND RESULTS Blood clots were produced in a femoral artery segment with endothelial damage and distal stenosis. Recombinant tissue-type plasminogen activator (rTPA) was infused at 30 micrograms.kg-1.min-1 for 60 minutes. Femoral artery flow was measured every 5 minutes for 2 hours. Rabbits were randomized to four groups with continuous wave ultrasound on or off with or without intravenous injection of 17 mg/kg aspirin (+US/-US/+Asp/-Asp). Ultrasound frequency and intensity were 1 MHz and 6.3 W/cm2. In seven of eight and five of five rabbits given rTPA and -US/-Asp or -US/+Asp, respectively, reflow was observed, persisting to the end of the observation period. In five of nine and four of five rabbits given rTPA and +US/-Asp or +US/+Asp, reflow was achieved, but persistent reocclusion was subsequently observed in five of five and two of four of these rabbits, respectively. Overall, femoral artery patency was worse and reocclusion occurred more often when ultrasound was added to rTPA (P = .002 by nonparametric ANOVA). However, initial reflow occurred more rapidly with ultrasound exposure (21 +/- 10 and 33 +/- 6 minutes for the +US/+Asp and +US/-Asp groups, respectively) compared with without ultrasound (46 +/- 13 and 74 +/- 14 minutes for the -US/+Asp and -US/-Asp groups, respectively) (P = .03 by ANOVA). CONCLUSIONS Although time to initial reflow was shortened by ultrasound, it was associated with less reperfusion and more reocclusion in this model. A possible explanation for these results is ultrasound-induced platelet activation counterbalancing its thrombolysis-accelerating effect.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 106 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3