Implantable transvenous cardioverter-defibrillators.

Author:

Bardy G H1,Hofer B1,Johnson G1,Kudenchuk P J1,Poole J E1,Dolack G L1,Gleva M1,Mitchell R1,Kelso D1

Affiliation:

1. Department of Medicine, University of Washington, Seattle.

Abstract

BACKGROUND Implantable transvenous cardioverter-defibrillators offer a significant opportunity to decrease procedural morbidity and medical costs in the care of patients with life-threatening ventricular arrhythmias who otherwise would have required a sternotomy or thoracotomy for device insertion. The purpose of this study was to examine prospectively the safety, efficacy, and limitations associated with the use of a transvenously implanted, tiered-therapy cardioverter-defibrillator with antitachycardia pacing function in a consecutive population of 84 ventricular fibrillation (VF) and sustained ventricular tachycardia (VT) survivors. METHODS AND RESULTS The index arrhythmia promoting transvenous cardioverter-defibrillator implantation was VF in 41 patients, VT in 27, and both VF and VT in 16. In each patient, transvenous defibrillation via a coronary sinus, a right ventricular, a superior vena caval, and/or a subcutaneous chest patch lead system was attempted. The pulsing methods used include two-electrode single-pathway pulsing or three-electrode dual-pathway simultaneous or sequential pulsing. A transvenous cardioverter-defibrillator was inserted if the defibrillation threshold (DFT) was < or = 20 J. Successful implantation of a transvenous cardioverter-defibrillator was possible in 80 of 84 (95%) patients. The mean implant DFT was 10.9 +/- 4.8 J. After cardioverter-defibrillator implantation, all patients were extubated in the operating room and sent to a standard telemetry ward for monitoring. No patient suffered a postoperative pulmonary complication or perioperative flurry of cardiac arrhythmias. Postoperative complications included lead dislodgments in eight, transient long thoracic nerve injury in one, asymptomatic left subclavian vein occlusion in two, asymptomatic small pericardial effusion in one, subcutaneous patch pocket hematomas in four, pulse generator pocket infection in one, and lead fracture in one. As experience was gained with the procedure, it was routine to discharge patients 3 days after surgery. The mean hospital stay was 6.0 +/- 2.4 days. Upon discharge, all patients returned to their prehospital activities including those with complications except for the patient with a pocket infection, who required intravenous antibiotic therapy. Patient survival using an intention-to-treat analysis was 98% over an 11 +/- 7-month follow-up period. During this time period, 31 of the 80 patients (39%) with transvenous lead systems were successfully treated by their device for sustained VT or VF. Antitachycardia pacing was used in 424 episodes of monomorphic VT and was successful in 371 (88%). All episodes of VF were aborted by the device. Antiarrhythmic drugs were used after device implantation in only eight of 80 patients (10%). CONCLUSIONS Transvenous cardioverter-defibrillator implantation is practical in most candidates. Implant DFTs are usually low, surgical morbidity and postoperative complications are modest, therapy of VT and VF is efficient, and survival is excellent.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 250 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3