Success, safety, and late electrophysiological outcome of low-energy direct-current ablation in patients with the Wolff-Parkinson-White syndrome.

Author:

Lemery R1,Talajic M1,Roy D1,Coutu B1,Lavoie L1,Lavallée E1,Cartier R1

Affiliation:

1. Department of Medicine, Montreal Heart Institute, Canada.

Abstract

BACKGROUND Percutaneous ablation of accessory pathways with the use of a defibrillator can be accomplished with high-energy direct-current (DC) shocks of 150-400 J, but complications include cardiac tamponade and sudden cardiac death, mostly resulting from significant electrical arcing and barotrauma. A new low-energy DC power source with a brief time-constant capacitive discharge delivers shocks of 2-40 J and eliminates or greatly reduces arcing. This report describes our initial experience with this device in 60 consecutive patients (mean age, 34 years; range, 9-67 years) with Wolff-Parkinson-White syndrome. Accessory pathways were located in the left free wall in 36 patients, in the right free wall in two, were posteroseptal in 18, and anteroseptal in four. Most patients (77%) had their initial diagnostic electrophysiological study and catheter ablation during the same session. METHODS AND RESULTS Selective ablation of accessory pathways was successful in 55 patients (92%). The mean cumulative energy was 312 +/- 284 J and the mean creatine kinase MB peak (normal, 0-30 units) was 42 +/- 27 units. Patients with left free wall accessory pathways required less procedure time for ablation (2.7 +/- 0.8 versus 3.6 +/- 1.5 hours, p less than 0.0007) and less fluoroscopy time (46 +/- 24 versus 66 +/- 33 minutes, p less than 0.002). Complications were limited to transient pericarditis (three patients), one iliac artery dissection, and cardiac tamponade probably caused by catheter repositioning in the coronary sinus (one patient). An electrophysiological study was repeated in 50 of the 55 successful cases at a mean of 9 +/- 5 months. This study was normal in 48 of 50 (96%) patients. CONCLUSIONS Low-energy DC ablation is safe and effective treatment for accessory pathways in children and adults. The long-term outcome is excellent as documented by electrophysiological restudy.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3