Left Atrial Volumes and Function by Three-Dimensional Echocardiography

Author:

Badano Luigi P.1,Miglioranza Marcelo H.1,Mihăilă Sorina1,Peluso Diletta1,Xhaxho Jola1,Marra Martina Perazzolo1,Cucchini Umberto1,Soriani Nicola1,Iliceto Sabino1,Muraru Denisa1

Affiliation:

1. From the Department of Cardiac, Thoracic and Vascular Sciences, University of Padua, Italy (L.P.B., D.P., J.X, M.P.M., U.C., N.S., S.I., D.M.); Cardiology Institute of Rio Grande do Sul, Porto Alegre, Brazil (M.H.M.); and Carol Davila University of Medicine and Pharmacy, Emergency University Hospital, Bucharest, Romania (S.M.).

Abstract

Background— Our study sought to (1) identify reference values for left atrial (LA) volumes and phasic function indices by 3-dimensional echocardiography (3DE) and compare them with those measured by 2-dimensional echocardiography (2DE) and (2) analyze their relationship with age, sex, body size, and left ventricular function. Accuracy and reproducibility of 3DE and 2DE have been also tested to evaluate the robustness of our data. Methods and Results— We obtained maximal, minimal, and preA LA volumes by 3DE and 2DE in 276 healthy volunteers (18–79 years; 57% women). Limits of normality for LA volumes and total LA emptying fraction were larger with 3DE than with 2DE (maximal LA volume: 43 versus 35 mL/m 2 ; preA LA volume: 31 versus 25 mL/m 2 ; minimal LA volume: 18 versus 14 mL/m 2 ; 53 versus 48%, respectively; P <0.001). 3DE LA volumes indexed by body surface area were similar in men and women and increased with age. On multivariable analysis, age, weight, and left ventricular systolic and diastolic function indices resulted as correlates of LA 3DE indices. LA volumes were tightly correlated with cardiac magnetic resonance measurements, yet more underestimated by 2DE versus 3DE (bias±SD: −17±16 versus −7±15 mL, respectively). Among all LA parameters, maximal LA volume and total emptying fraction were the most reproducible, including at test-retest and at expert versus trainee comparisons. Conclusions— This study provides reference values for LA 3DE volumes and function from a relatively large cohort of healthy subjects with a wide age range. Our data may help clinicians to identify LA remodeling and dysfunction.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3