Doppler-Derived Arterial Load Indices Better Reflect Left Ventricular Afterload Than Systolic Blood Pressure in Coarctation of Aorta

Author:

Egbe Alexander C.1,Reddy Yogesh N.V.1,Obokata Masaru1,Borlaug Barry A.1

Affiliation:

1. Department of Cardiovascular Medicine, Mayo Clinic Rochester, MN.

Abstract

Background: Patients with vascular stiffening may display increased arterial afterload that is out of proportion to systolic blood pressure (SBP). Since vascular and endothelial dysfunction develop in patients with coarctation of aorta (COA), we hypothesized that for any SBP, patients with mild COA (COA peak velocity <2 m/s) will have a higher arterial afterload and increased left ventricular mass index (LVMI) compared with controls, and that Doppler-derived arterial load indices would be a better predictor of LVMI compared with SBP alone. Methods: We studied 204 COA patients (age 35±12 y) and 204 matched controls. Doppler-derived arterial afterload was assessed using effective arterial elastance index and total arterial compliance index. Results: Despite similar SBP, the mild COA group displayed higher arterial afterload as evidenced by a higher elastance index (3.3±0.9 versus 2.9±0.7 mm Hg/mL·m 2 ; P <0.001) and lower total arterial compliance index (0.8±0.3 versus 1.2±0.5 mL/mm Hg·m 2 ; P <0.001). This was associated with higher LVMI in COA (109±35 versus 93±32, g/m 2 ; P <0.001). Compared with SBP (β=0.24 [95% CI, 0.02–0.45]), elastance index (β=20.2 [95% CI, 15.8–44.1]) and total arterial compliance index (β=−32.5 [95% CI, −43.8 to −123.6]) were better predictors of LVMI. Elastance index (but not SBP) was predictive of longitudinal increases in LVMI ( r =0.43, P <0.001). Conclusions: COA patients had higher arterial afterload compared with controls with similar SBP. In comparison to SBP, Doppler-derived arterial load indices correlate more strongly with LV hypertrophy. These data suggest that SBP may underestimate LV afterload in this population. This has important clinical implications since titration of antihypertensive therapy is currently based on SBP.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3