New Electrocardiographic Algorithm for the Diagnosis of Acute Myocardial Infarction in Patients With Left Bundle Branch Block

Author:

Di Marco Andrea1,Rodriguez Marcos1,Cinca Juan2,Bayes‐Genis Antoni3,Ortiz‐Perez Jose T.4,Ariza‐Solé Albert1,Sanchez‐Salado Jose Carlos1,Sionis Alessandro2,Rodriguez Jany4,Toledano Beatriz3,Codina Pau3,Solé‐González Eduard2,Masotti Monica4,Gómez‐Hospital Joan Antoni1,Cequier Ángel1,Anguera Ignasi1

Affiliation:

1. Heart Disease Institute Bellvitge University Hospital Barcelona Spain

2. Cardiology Department Hospital de la Santa Creu I Sant Pau IIB‐Santpau CIBERCV Universitat Autonoma de Barcelona Spain

3. Cardiology Department Germans Trias i Pujol University Hospital CIBERCV Badalona Spain

4. Cardiology Department Hospital Clinic CIBERCV Barcelona Spain

Abstract

Background Current electrocardiographic algorithms lack sensitivity to diagnose acute myocardial infarction ( AMI ) in the presence of left bundle branch block. Methods and Results A multicenter retrospective cohort study including consecutive patients with suspected AMI and left bundle branch block, referred for primary percutaneous coronary intervention between 2009 and 2018. Pre‐2015 patients formed the derivation cohort (n=163, 61 with AMI ); patients between 2015 and 2018 formed the validation cohort (n=107, 40 with AMI ). A control group of patients without suspected AMI was also studied (n=214). Different electrocardiographic criteria were tested. A total of 484 patients were studied. A new electrocardiographic algorithm ( BARCELONA algorithm) was derived and validated. The algorithm is positive in the presence of ST deviation ≥1 mm (0.1 mV) concordant with QRS polarity, in any lead, or ST deviation ≥1 mm (0.1 mV) discordant with the QRS , in leads with max (R|S) voltage (the voltage of the largest deflection of the QRS , ie, R or S wave) ≤6 mm (0.6 mV). In both the derivation and the validation cohort, the BARCELONA algorithm achieved the highest sensitivity (93%–95%), negative predictive value (96%–97%), efficiency (91%–94%) and area under the receiver operating characteristic curve (0.92–0.93), significantly higher than previous electrocardiographic rules ( P <0.01); the specificity was good in both groups (89%–94%) as well as the control group (90%). Conclusions In patients with left bundle branch block referred for primary percutaneous coronary intervention , the BARCELONA algorithm was specific and highly sensitive for the diagnosis of AMI , leading to a diagnostic accuracy comparable to that obtained by ECG in patients without left bundle branch block.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

Cited by 30 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3