Diagnosis of Thin-Capped Fibroatheromas in Intravascular Optical Coherence Tomography Images

Author:

Phipps Jennifer E.1,Hoyt Taylor1,Vela Deborah1,Wang Tianyi1,Michalek Joel E.1,Buja L. Maximilian1,Jang Ik-Kyung1,Milner Thomas E.1,Feldman Marc D.1

Affiliation:

1. From the Department of Medicine (J.E.P., T.H., M.D.F.) and Epidemiology and Biostatistics (J.E.M.), University of Texas Health Science Center San Antonio; Department of Cardiovascular Pathology, Texas Heart Institute, Houston (D.V., L.M.B.); Department of Biomedical Engineering, University of Texas at Austin (T.W., T.E.M.); Department of Medicine, Massachusetts General Hospital, Harvard Medical School, Boston (I.-K.J.); and Department of Veterans Affairs, South Texas Veterans Health Care System, San...

Abstract

Background— Intravascular optical coherence tomography (IVOCT) images are recorded by detecting light backscattered within coronary arteries. We hypothesize that non–thin-capped fibroatheroma (TCFA) causes may scatter light to create the false appearance of IVOCT TCFA. Methods and Results— Ten human cadaver hearts were imaged with IVOCT (n=14 coronary arteries). IVOCT and histological TCFA images were coregistered and compared. Of 21 IVOCT TCFAs (fibrous cap <65 μm, lipid arc >1 quadrant), only 8 were true histological TCFA. Foam cell infiltration was responsible for 70% of false IVOCT TCFA and caused both thick-capped fibroatheromas to appear as TCFA, and the appearance of TCFAs when no lipid core was present. Other false IVOCT TCFA causes included smooth muscle cell–rich fibrous tissue (12%) and loose connective tissue (9%). If the lipid arc >1 quadrant (obtuse) criterion was disregarded, 45 IVOCT TCFAs were identified, and sensitivity of IVOCT TCFA detection increased from 63% to 87%, and specificity remained high at 92%. Conclusions— We demonstrate that IVOCT can exhibit 87% (95% CI, 75%–93%) sensitivity and 92% specificity (95% CI, 86%–96%) to detect all lipid arcs (both obtuse and acute, <1 quadrant) TCFA, and we also propose new mechanisms involving light scattering that explain why other plaque components can masquerade as TCFA and cause low positive predictive value of IVOCT for TCFA detection (47% for obtuse lipid arcs). Disregarding the lipid arc >1 quadrant requirement enhances the ability of IVOCT to detect TCFA.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

Cited by 38 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3