Real-Time Magnetic Resonance Imaging–Guided Stenting of Aortic Coarctation With Commercially Available Catheter Devices in Swine

Author:

Raval Amish N.1,Telep James D.1,Guttman Michael A.1,Ozturk Cengizhan1,Jones Michael1,Thompson Richard B.1,Wright Victor J.1,Schenke William H.1,DeSilva Ranil1,Aviles Ronnier J.1,Raman Venkatesh K.1,Slack Michael C.1,Lederman Robert J.1

Affiliation:

1. From the Cardiovascular Branch (A.N.R., J.D.T., C.O., M.J., V.K.R., V.J.W., W.H.S., R.D.S., R.J.A., R.J.L.) and the Laboratory of Cardiac Energetics (M.A.G., R.B.T., E.R.M.), Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Md; Division of Pediatric Cardiology (J.D.T., M.C.S.), Children’s National Medical Center, Washington, DC; and Department of Biomedical Engineering (R.B.T.), University of Alberta, Edmonton, Canada.

Abstract

Background— Real-time MR imaging (rtMRI) is now technically capable of guiding catheter-based cardiovascular interventions. Compared with x-ray, rtMRI offers superior tissue imaging in any orientation without ionizing radiation. Translation to clinical trials has awaited the availability of clinical-grade catheter devices that are both MRI visible and safe. We report a preclinical safety and feasibility study of rtMRI-guided stenting in a porcine model of aortic coarctation using only commercially available catheter devices. Method and Results— Coarctation stenting was performed wholly under rtMRI guidance in 13 swine. rtMRI permitted procedure planning, device tracking, and accurate stent deployment. “Active” guidewires, incorporating MRI antennas, improved device visualization compared with unmodified “passive” nitinol guidewires and shortened procedure time (26±11 versus 106±42 minutes; P =0.008). Follow-up catheterization and necropsy showed accurate stent deployment, durable gradient reduction, and appropriate neointimal formation. MRI immediately identified aortic rupture when oversized devices were tested. Conclusions— This experience demonstrates preclinical safety and feasibility of rtMRI-guided aortic coarctation stenting using commercially available catheter devices. Patients may benefit from rtMRI in the future because of combined device and tissue imaging, freedom from ionizing radiation, and the ability to identify serious complications promptly.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 73 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3