Impact of Practice-Based Management of Pulmonary Artery Pressures in 2000 Patients Implanted With the CardioMEMS Sensor

Author:

Heywood J. Thomas1,Jermyn Rita1,Shavelle David1,Abraham William T.1,Bhimaraj Arvind1,Bhatt Kunjan1,Sheikh Fareed1,Eichorn Eric1,Lamba Sumant1,Bharmi Rupinder1,Agarwal Rahul1,Kumar Charisma1,Stevenson Lynne W.1

Affiliation:

1. From the Division of Cardiology, Scripps Clinic Torrey Pines, La Jolla, CA (J.T.H.); St. Francis Hospital, Roslyn, NY (R.J.); Division of Cardiovascular Medicine, Keck School of Medicine, Los Angeles, CA (D.S.); The Ohio State University, Columbus (W.T.A.); Houston Methodist Hospital, TX (A.B.); Austin Heart Hospital, Austin, TX (K.B.); St. Rose Dominican Hospital, Las Vegas, NV (F.S.); Medical City of Dallas, TX (E.E.); First Coast Cardiovascular Institute, Jacksonville, FL (S.L.); Clinical...

Abstract

Background: Elevated pulmonary artery (PA) pressures in patients with heart failure are associated with a high risk for hospitalization and mortality. Recent clinical trial evidence demonstrated a direct relationship between lowering remotely monitored PA pressures and heart failure hospitalization risk reduction with a novel implantable PA pressure monitoring system (CardioMEMS HF System, St. Jude Medical). This study examines PA pressure changes in the first 2000 US patients implanted in general practice use. Methods: Deidentified data from the remote monitoring Merlin.net (St. Jude Medical) database were used to examine PA pressure trends from the first consecutive 2000 patients with at least 6 months of follow-up. Changes in PA pressures were evaluated with an area under the curve methodology to estimate the total sum increase or decrease in pressures (mm Hg-day) during the follow-up period relative to the baseline pressure. As a reference, the PA pressure trends were compared with the historic CHAMPION clinical trial (CardioMEMS Heart Sensor Allows Monitoring of Pressure to Improve Outcomes in New York Heart Association [NYHA] Functional Class III Heart Failure Patients). The area under the curve results are presented as mean±2 SE, and P values comparing the area under the curve of the general-use cohort with outcomes in the CHAMPION trial were computed by the t test with equal variance. Results: Patients were on average 70±12 years old; 60% were male; 34% had preserved ejection fraction; and patients were followed up for an average of 333±125 days. At implantation, the mean PA pressure for the general-use patients was 34.9±10.2 mm Hg compared with 31.3±10.9 mm Hg for CHAMPION treatment and 32.0±10.5 mm Hg for CHAMPION control groups. The general-use patients had an area under the curve of −32.8 mm Hg-day at the 1-month time mark, −156.2 mm Hg-day at the 3-month time mark, and −434.0 mm Hg-day after 6 months of hemodynamic guided care, which was significantly lower than the treatment group in the CHAMPION trial. Patients consistently transmitted pressure information with a median of 1.27 days between transmissions after 6 months. Conclusions: The first 2000 general-use patients managed with hemodynamic-guided heart failure care had higher PA pressures at baseline and experienced greater reduction in PA pressure over time compared with the pivotal CHAMPION clinical trial. These data demonstrate that general use of implantable hemodynamic technology in a nontrial setting leads to significant lowering of PA pressures.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 123 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3