Background— Prosthesis–patient size mismatch results when an implanted prosthetic aortic valve is of insufficient size for a patient’s body surface area. The relation between prosthesis–patient size and functional capacity and adverse postoperative outcome is inconsistent. Our objectives were to examine the impact of valve replacement, continuous prosthesis–patient size, and other factors on functional recovery after aortic valve replacement (AVR) with the Duke Activity Status Index (DASI). Methods and Results— From June 15, 1995, through May 14, 1998, 1108 patients underwent AVR after completing a DASI survey. Of these, 1014 completed a postoperative DASI survey at an average of 8.3 months postoperatively. Logistic ordinal regression was used to examine the influence of demographic variables, comorbidities, baseline DASI scores, indexed valve orifice area, standardized orifice size, and postoperative morbid events on postoperative DASI. There was overall improvement in postoperative functional recovery reflected by median preoperative and postoperative DASI scores of 29 and 46, P <0.001, respectively. Neither indexed orifice area, P =0.94, nor standardized orifice size, P =0.96, was associated with functional recovery. Female sex, increasing age, elevated serum creatinine, increased central venous pressure, and red blood cell transfusion were factors associated with poor postoperative functional recovery. Conclusions— A majority of patients report improvement in functional quality of life early after AVR. Similar functional recovery was demonstrated for patients along the full spectrum of valve sizes indexed to body size, even for values considered to represent severe mismatch for patient size. Factors other than prosthesis–patient size influence functional quality of life early after AVR.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 77 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3