Comparison of Self-Expanding Bioprostheses for Transcatheter Aortic Valve Replacement in Patients With Symptomatic Severe Aortic Stenosis

Author:

Tamburino Corrado1,Bleiziffer Sabine2,Thiele Holger3,Scholtz Smita4,Hildick-Smith David5,Cunnington Michael6,Wolf Alexander7,Barbanti Marco8,Tchetchè Didier9,Garot Philippe10ORCID,Pagnotta Paolo11,Gilard Martine12,Bedogni Francesco13,Van Belle Eric14,Vasa-Nicotera Mariuca15ORCID,Chieffo Alaide16,Deutsch Oliver17ORCID,Kempfert Jörg18,Søndergaard Lars19,Butter Christian20,Trillo-Nouche Ramiro21,Lotfi Shahram22,Möllmann Helge23,Joner Michael24,Abdel-Wahab Mohamed3ORCID,Bogaerts Kris2526,Hengstenberg Christian27,Capodanno Davide1

Affiliation:

1. Department of General Surgery and Medical-Surgical Subspecialties, University of Catania, Italy (C.T., D.C.).

2. Department of Cardiothoracic Surgery (S.B.), Heart and Diabetes Center Northrhein-Westfalia, Bad Oeynhausen, Germany.

3. Department of Cardiology, Heart Center Leipzig at University Leipzig, Germany (H.T., M.A.-W.).

4. Department of Interventional Cardiology (S.S.), Heart and Diabetes Center Northrhein-Westfalia, Bad Oeynhausen, Germany.

5. Department of Cardiology, Brighton and Sussex University Hospitals National Health Service Trust, Brighton, United Kingdom (D.H.-S.).

6. Department of Cardiology, Leeds General Infirmary, Leeds Teaching Hospitals National Health Service Trust, United Kingdom (M.C.).

7. Department of Cardiology, Elisabeth Hospital Essen, Germany (A.W.).

8. Department of Cardio-Thoracic-Vascular Diseases and Transplantations, Azienda Ospedaliero-Universitaria Policlinico “G. Rodolico-San Marco,” Catania, Italy (M.B.).

9. Groupe CardioVasculaire Interventionnel, Clinique Pasteur, Toulouse, France (D.T.).

10. Hôpital Privé Jacques Cartier, Institut Cardio-vasculaire Paris-Sud, Ramsay-Santé, Massy, France (P.G.).

11. Department of Cardiovascular Medicine, Humanitas Clinical and Research Center, Milano, Italy (P.P.).

12. Department of Cardiology, Brest University Hospital, France (M.G.).

13. Cardiology Department, Istituti di Ricovero e Cura a Carattere Scientifico Policlinico San Donato, Milano, Italy (F.B.).

14. Department of Cardiology, University Hospital, Lille, France (E.V.B.).

15. Department of Cardiology, Goethe University Hospital Frankfurt, Frankfurt am Main, Germany (M.V.-N.).

16. Interventional Cardiology Unit, Istituti di Ricovero e Cura a Carattere Scientifico San Raffaele Scientific Institute, Milan, Italy (A.C.).

17. Department of Cardiovascular Surgery, German Heart Centre Munich, Germany (O.D.).

18. Deutsches Herzzentrum Berlin, Charité Universitätsmedizin, Berlin, Germany (J.K.).

19. The Heart Center-Rigshospitalet, Copenhagen, Denmark (L.S.).

20. Department of Cardiology, Heart Center Brandenburg in Bernau and Brandenburg Medical School, Germany (C.B.).

21. Servicio de Cardiología, Complejo Hospitalario Universitario de Santiago de Compostela, Spain (R.T.-N.).

22. Department of Cardiovascular Surgery, University Hospital RWTH Aachen, Germany (S.L.).

23. Department of Cardiology, St Johannes Hospital, Dortmund, Germany (H.M.).

24. Klinik für Herz und Kreislauferkrankungen, Deutsches Herzzentrum München, Munich, Germany (M.J.).

25. Department of Public Health and Primary Care, I-BioStat, KU Leuven, Belgium (K.B.).

26. I-BioStat, Universiteit Hasselt, Belgium (K.B.).

27. Department of Internal Medicine II, Medical University of Vienna, Austria (C.H.).

Abstract

Background: Few randomized trials have compared bioprostheses for transcatheter aortic valve replacement, and no trials have compared bioprostheses with supra-annular design. The SCOPE 2 trial (Safety and Efficacy Comparison of Two TAVI Systems in a Prospective Randomized Evaluation 2) was designed to compare the clinical outcomes of the ACURATE neo and CoreValve Evolut bioprostheses for transcatheter aortic valve replacement. Methods: SCOPE 2 was a randomized trial performed at 23 centers in 6 countries between April 2017 and April 2019. Patients ≥75 years old with an indication for transfemoral transcatheter aortic valve replacement as agreed by the heart team were randomly assigned to receive treatment with either the ACURATE neo (n=398) or the CoreValve Evolut bioprostheses (n=398). The primary end point, powered for noninferiority of the ACURATE neo bioprosthesis, was all-cause death or stroke at 1 year. The key secondary end point, powered for superiority of the ACURATE neo bioprosthesis, was new permanent pacemaker implantation at 30 days. Results: Among 796 randomized patients (mean age, 83.2±4.3 years; mean Society of Thoracic Surgeons Predicted Risk of Mortality score, 4.6±2.9%), clinical follow-up information was available for 778 (98%) patients. Within 1 year, the primary end point occurred in 15.8% of patients in the ACURATE neo group and in 13.9% of patients in the CoreValve Evolut group (absolute risk difference, 1.8%, upper 1-sided 95% confidence limit, 6.1%; P =0.0549 for noninferiority). The 30-day rates of new permanent pacemaker implantation were 10.5% in the ACURATE neo group and 18.0% in the CoreValve Evolut group (absolute risk difference, –7.5% [95% CI, –12.4 to –2.60]; P =0.0027). No significant differences were observed in the components of the primary end point. Cardiac death at 30 days (2.8% versus 0.8%; P =0.03) and 1 year (8.4% versus 3.9%; P =0.01), and moderate or severe aortic regurgitation at 30 days (10% versus 3%; P =0.002) were significantly increased in the ACURATE neo group. Conclusions: Transfemoral transcatheter aortic valve replacement with the self-expanding ACURATE neo did not meet noninferiority compared with the self-expanding CoreValve Evolut in terms of all-cause death or stroke at 1 year, and it was associated with a lower incidence of new permanent pacemaker implantation. In secondary analyses, the ACURATE neo was associated with more moderate or severe aortic regurgitation at 30 days and cardiac death at 30 days and 1 year. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03192813.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 96 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3