Magnetic Resonance Imaging–Guided Balloon Angioplasty of Coarctation of the Aorta

Author:

Krueger Julia J.1,Ewert Peter1,Yilmaz Sevim1,Gelernter Dinah1,Peters Björn1,Pietzner Klaus1,Bornstedt Axel1,Schnackenburg Bernhard1,Abdul-Khaliq Hashim1,Fleck Eckart1,Nagel Eike1,Berger Felix1,Kuehne Titus1

Affiliation:

1. From the Departments of Congenital Heart Disease and Pediatric Cardiology (J.J.K., P.E., S.Y., D.G., B.P., K.P., H.A.-K., F.B., T.K.) and Cardiology (A.B., E.F., E.N.), Deutsches Herzzentrum Berlin, Berlin, Germany, and Clinical Science Philips (B.S.), Hamburg, Germany.

Abstract

Background— MRI guidance of percutaneous transluminal balloon angioplasty (PTA) of aortic coarctation (CoA) would be desirable for continuous visualization of anatomy and to eliminate x-ray exposure. The aim of this study was (1) to determine the suitability of MRI-controlled PTA using the iron oxide–based contrast medium Resovist (ferucarbotran) for catheter visualization and (2) to subsequently apply this technique in a pilot study with patients with CoA. Methods and Results— The MRI contrast-to-noise ratio and artifact behavior of Resovist-treated balloon catheters was optimized in in vitro and animal experiments (pigs). In 5 patients, anatomy of the CoA was evaluated before and after intervention with high-resolution respiratory-navigated 3D MRI and multiphase cine MRI. Position monitoring of Resovist-treated catheters was realized with interactive real-time MRI. Aortic pressures were continuously recorded. Conventional catheterization was performed before and after MRI to confirm interventional success. During MRI, catheters filled with 25 μmol of iron particles per milliliter of Resovist produced good signal contrast between catheters and their background anatomy but no image distortion due to susceptibility artifacts. All MRI procedures were performed successfully in the patient study. There was excellent agreement between the diameters of CoA and pressure gradients as measured during MRI and conventional catheterization. In 4 patients, PTA resulted in substantial widening of the CoA and a decrease in pressure gradients. In 1 patient, PTA was ineffective. Conclusions— The MRI method described represents a potential alternative to conventional x-ray fluoroscopy for catheter-based treatment of patients with CoA.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 73 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3