Effects of Cardiac Resynchronization Therapy With or Without a Defibrillator on Survival and Hospitalizations in Patients With New York Heart Association Class IV Heart Failure

Author:

Lindenfeld JoAnn1,Feldman Arthur M.1,Saxon Leslie1,Boehmer John1,Carson Peter1,Ghali Jalal K.1,Anand Inder1,Singh Steve1,Steinberg Jonathan S.1,Jaski Brian1,DeMarco Teresa1,Mann David1,Yong Patrick1,Galle Elizabeth1,Ecklund Fred1,Bristow Michael1

Affiliation:

1. From the Department of Medicine, University of Colorado Health Sciences Center (J.L., M.R.B.), and Women’s Health Research Center (J.L.), Denver, Colo; Thomas Jefferson Medical College (A.M.F.), Philadelphia, Pa; University of Southern California (Keck School of Medicine) (L.A.S.), Los Angeles; Milton Hershey Medical Center, Penn State School of Medicine (J.B.), Hershey, Pa; Washington DC Veterans Administration (S.S., P.C.), Washington, DC; Wayne State School of Medicine (J.K.G.), Detroit, Mich;...

Abstract

Background— Cardiac resynchronization therapy (CRT) alone or combined with an implantable defibrillator (CRT-D) has been shown to improve exercise capacity and quality of life and to reduce heart failure (HF) hospitalizations and mortality in patients with New York Heart Association (NYHA) class III and IV HF. There is concern that the device procedure may destabilize these very ill class IV patients. We sought to examine the outcomes of NYHA class IV patients enrolled in the Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure (COMPANION) trial to assess the potential benefits of CRT and CRT-D. Methods and Results— The COMPANION trial randomized 1520 patients with NYHA class III and IV HF to optimal medical therapy, CRT, or CRT-D. In the class IV patients (n=217), the primary end point of time to death or hospitalization for any cause was significantly improved by both CRT (hazard ratio [HR], 0.64; 95% CI, 0.43 to 0.94; P =0.02) and CRT-D (HR, 0.62; 95% CI, 0.42 to 0.90; P =0.01). Time to all-cause death and HF hospitalization was also significantly improved in both CRT (HR, 0.57; 95% CI, 0.37 to 0.87; P =0.01) and CRT-D (HR, 0.49; 95% CI, 0.32 to 0.75; P =0.001) Time to all-cause death trended to an improvement in both CRT (HR, 0.67; 95% CI, 0.41 to 1.10; P =0.11) and CRT-D (HR, 0.63; 95% CI, 0.39 to 1.03; P =0.06). Time to sudden death appeared to be significantly reduced in the CRT-D group (HR, 0.27; 95% CI, 0.08 to 0.90; P =0.03). There was a nonsignificant reduction in time to HF deaths for both CRT (HR, 0.68; 95% CI, 0.34 to 1.37; P =0.28) and CRT-D (HR, 0.79; 95% CI, 0.41 to 1.52; P =0.48). Conclusions— CRT and CRT-D significantly improve time to all-cause mortality and hospitalizations in NYHA class IV patients, with a trend for improved mortality. These devices should be considered in ambulatory NYHA class IV HF patients similar to those enrolled in COMPANION.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3