Delayed Coverage in Malapposed and Side-Branch Struts With Respect to Well-Apposed Struts in Drug-Eluting Stents

Author:

Gutiérrez-Chico Juan Luis1,Regar Evelyn1,Nüesch Eveline1,Okamura Takayuki1,Wykrzykowska Joanna1,di Mario Carlo1,Windecker Stephan1,van Es Gerrit-Anne1,Gobbens Pierre1,Jüni Peter1,Serruys Patrick W.1

Affiliation:

1. From the Erasmus Medical Centre, Thoraxcentre, Rotterdam, Netherlands (J.L.G.-C., E.R., T.O., J.W., P.W.S.); Institute for Social and Preventive Medicine, University of Bern, Bern, Switzerland (E.N., P.J.); CTU Bern, Bern University Hospital, Bern, Switzerland (E.N., P.J.); Royal Brompton Hospital, London, UK (C.d.M.); Schweizerisches HerzzentrumûInselspital, Bern, Switzerland (S.W.); and Cardialysis BV, Rotterdam, Netherlands (G.v.E., P.G.).

Abstract

Background— Pathology studies on fatal cases of very late stent thrombosis have described incomplete neointimal coverage as common substrate, in some cases appearing at side-branch struts. Intravascular ultrasound studies have described the association between incomplete stent apposition (ISA) and stent thrombosis, but the mechanism explaining this association remains unclear. Whether the neointimal coverage of nonapposed side-branch and ISA struts is delayed with respect to well-apposed struts is unknown. Methods and Results— Optical coherence tomography studies from 178 stents implanted in 99 patients from 2 randomized trials were analyzed at 9 to 13 months of follow-up. The sample included 38 sirolimus-eluting, 33 biolimus-eluting, 57 everolimus-eluting, and 50 zotarolimus-eluting stents. Optical coherence tomography coverage of nonapposed side-branch and ISA struts was compared with well-apposed struts of the same stent by statistical pooled analysis with a random-effects model. A total of 34 120 struts were analyzed. The risk ratio of delayed coverage was 9.00 (95% confidence interval, 6.58 to 12.32) for nonapposed side-branch versus well-apposed struts, 9.10 (95% confidence interval, 7.34 to 11.28) for ISA versus well-apposed struts, and 1.73 (95% confidence interval, 1.34 to 2.23) for ISA versus nonapposed side-branch struts. Heterogeneity of the effect was observed in the comparison of ISA versus well-apposed struts (H=1.27; I 2 =38.40) but not in the other comparisons. Conclusions— Coverage of ISA and nonapposed side-branch struts is delayed with respect to well-apposed struts in drug-eluting stents, as assessed by optical coherence tomography. Clinical Trial Registration— http://www.clinicaltrials.gov . Unique identifier: NCT00389220, NCT00617084.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3