Durable Polymer Versus Biodegradable Polymer Drug-Eluting Stents After Percutaneous Coronary Intervention in Patients with Acute Coronary Syndrome

Author:

Kim Hyo-Soo1ORCID,Kang Jeehoon1,Hwang Doyeon1,Han Jung-Kyu1ORCID,Yang Han-Mo1ORCID,Kang Hyun-Jae1,Koo Bon-Kwon1ORCID,Kim Seok Yeon2,Park Keun-Ho3,Rha Seung-Woon4,Shin Won-Yong5,Lim Hong-Seok6,Park Kyungil7ORCID,Park Kyung Woo1ORCID,

Affiliation:

1. Seoul National University Hospital, Korea (H-S.K., J.K., D.H., J-K.H., H-M.Y., H-J.K., B-K.K., K.W.P.).

2. Seoul Medical Center, Korea (S.Y.K.).

3. Chosun University Hospital, Gwangju, Korea (K-H.P.).

4. Korea University Guro Hospital, Seoul, Korea (S-W.R.).

5. Soon Chun Hyang University Cheonan Hospital, Cheonan, Korea (W-Y.S.).

6. Ajou University School of Medicine, Suwon, Korea (H-S.L.).

7. Dong-A University Hospital, Busan, Korea (K.P.).

Abstract

Background: Large-scale randomized comparison of drug-eluting stents (DES) based on durable polymer versus biodegradable polymer technology is currently insufficient in patients with acute coronary syndrome (ACS). The present study aimed to prove the noninferiority of the durable polymer DES (DP-DES) compared with the biodegradable polymer DES (BP-DES) in such patients. Methods: The HOST-REDUCE-POLYTECH-ACS (Harmonizing Optimal Strategy for Treatment of Coronary Artery Diseases—Comparison of Reduction of Prasugrel Dose or Polymer Technology in ACS Patients) trial is an investigator-initiated, randomized, open-label, adjudicator-blinded, multicenter, noninferiority trial comparing the efficacy and safety of DP-DES and BP-DES in patients with ACS. The primary end point was a patient-oriented composite outcome (a composite of all-cause death, nonfatal myocardial infarction, and any repeat revascularization) at 12 months. The key secondary end point was device-oriented composite outcome (a composite of cardiac death, target-vessel myocardial infarction, or target lesion revascularization) at 12 months. Results: A total of 3413 patients were randomized to receive the DP-DES (1713 patients) and BP-DES (1700 patients). At 12 months, patient-oriented composite outcome occurred in 5.2% in the DP-DES group and 6.4% in the BP-DES group (absolute risk difference, –1.2%; P non inferiority <0.001). The key secondary end point, device-oriented composite outcome, occurred less frequently in the DP-DES group (DP-DES vs BP-DES, 2.6% vs 3.9%; hazard ratio, 0.67 [95% CI, 0.46–0.98]; P =0.038), mostly because of a reduction in target lesion revascularization. The rate of spontaneous nonfatal myocardial infarction and stent thrombosis were extremely low, with no significant difference between the 2 groups (0.6% versus 0.8%; P =0.513 and 0.1% versus 0.4%; P =0.174, respectively). Conclusions: In ACS patients receiving percutaneous coronary intervention, DP-DES was noninferior to BP-DES with regard to patient-oriented composite outcomes at 12 months after index percutaneous coronary intervention. Registration: URL: https://wwwclinicaltrials.gov ; Unique identifier: NCT02193971.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3