Noninvasive Assessment of Myocardial Inflammation by Cardiovascular Magnetic Resonance in a Rat Model of Experimental Autoimmune Myocarditis

Author:

Moon Hyeyoung1,Park Hyo Eun1,Kang Jongeun1,Lee Hyunseung1,Cheong Chaejoon1,Lim Yong Taik1,Ihm Sang-Hyun1,Seung Ki-Bae1,Jaffer Farouc A.1,Narula Jagat1,Chang Kiyuk1,Hong Kwan Soo1

Affiliation:

1. From the Division of MR Research, Korea Basic Science Institute, Cheongwon (H.M., J.K., H.L., C.C., K.S.H.); Department of Bioanalytical Science, University of Science and Technology, Daejeon (H.M., K.S.H.); Cardiovascular Center, Seoul St. Mary's Hospital. Seoul (H.E.P., S.-H.I., K.-B.S., K.C.); Department of Cardiovascular Medicine, College of Medicine, Catholic University of Korea, Seoul (H.E.P., S.-H.I., K.-B.S., K.C.); Graduate School of Analytical Science and Technology, Chungnam National...

Abstract

Background— Limited availability of noninvasive and biologically precise diagnostic tools poses a challenge for the evaluation and management of patients with myocarditis. Methods and Results— The feasibility of cardiovascular magnetic resonance (CMR) imaging with magneto-fluorescent nanoparticles (MNPs) for detection of myocarditis and its effectiveness in discriminating inflammation grades were assessed in experimental autoimmune myocarditis (EAM) (n=65) and control (n=10) rats. After undergoing CMR, rats were administered with MNPs, followed by a second CMR 24 hours later. Head-to-head comparison of MNP-CMR with T 2 -weighted, early and late gadolinium enhancement CMR was performed in additional EAM (n=10) and control (n=5) rats. Contrast-to-noise ratios were measured and compared between groups. Flow cytometry and microscopy demonstrated that infiltrating inflammatory cells engulfed MNPs, resulting in altered myocardial T 2 * effect. Changes in contrast-to-noise ratio between pre- and post-MNP CMR were significantly greater in EAM rats (1.08±0.10 versus 0.48±0.20; P <0.001). In addition, contrast-to-noise ratio measurement in MNP-CMR clearly detected the extent of inflammation ( P <0.001) except for mild inflammation. Compared with conventional CMR, MNP-CMR provided better image contrast (CNR change 8% versus 46%, P <0.001) and detectability of focal myocardial inflammation. Notably, MNP-CMR successfully tracked the evolution of myocardial inflammation in the same EAM rats. Conclusions— Magneto-fluorescent nanoparticle CMR permitted effective visualization of myocardial inflammatory cellular infiltrates and distinction of the extent of inflammation compared with conventional CMR in a preclinical model of EAM. Magneto-fluorescent nanoparticle CMR performs best in EAM rats with at least moderate inflammatory response.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3