Molecular Magnetic Resonance Imaging of Atrial Clots in a Swine Model

Author:

Spuentrup Elmar1,Fausten Bernd1,Kinzel Sylvia1,Wiethoff Andrea J.1,Botnar Rene M.1,Graham Philip B.1,Haller Stephan1,Katoh Marcus1,Parsons Edward C.1,Manning Warren J.1,Busch Thomas1,Günther Rolf W.1,Buecker Arno1

Affiliation:

1. From the Departments of Diagnostic Radiology (E.S., S.H., M.K., R.W.G., A.B.), Thoracic and Cardiovascular Surgery (B.F., T.B.), and Laboratory Animal Science (S.K.), Aachen Technical University, Aachen, Germany; EPIX Pharmaceuticals (A.J.W., P.B.G., E.C.P.), Cambridge, Mass; and the Departments of Medicine, Cardiovascular Division (R.M.B., W.J.M.), and Radiology (W.J.M.), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Mass.

Abstract

Background— The detection and differentiation of intracardiac masses is still challenging and may include neoplasms and thrombi. The aim of this study was the investigation of a targeted, fibrin-specific contrast agent (EP-2104R) for molecular targeted magnetic resonance imaging (MRI) of left atrial clots. Methods and Results— Chronic human thrombi were surgically implanted in the left atrial appendage of 5 swine. Molecular MRI was performed with a navigator-gated, free-breathing, cardiac-triggered 3D inversion-recovery, black-blood, gradient-echo sequence before and after systemic administration of 4 μmol/kg EP-2104R. MR images were analyzed by 2 investigators, and the contrast-to-noise ratio was calculated. Location of clots was confirmed by autopsy, and the gadolinium concentration in the clots was assessed. Before contrast agent administration, thrombi were not visible on black-blood MR images. After contrast administration, all atrial clots (n=5) were selectively visualized as white spots with a high contrast-to-noise ratio (clot/blood, 29.7±8.0). The gadolinium concentration in the clots averaged 74±45 μmol/L. Conclusions— The fibrin-specific MR contrast agent EP-2104R allows for selective and high-contrast visualization of left atrial clots by means of molecular targeted MRI.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 89 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3