Assessment of the European Society of Cardiology 0-Hour/1-Hour Algorithm to Rule-Out and Rule-In Acute Myocardial Infarction

Author:

Pickering John W.1,Greenslade Jaimi H.1,Cullen Louise1,Flaws Dylan1,Parsonage William1,Aldous Sally1,George Peter1,Worster Andrew1,Kavsak Peter A.1,Than Martin P.1

Affiliation:

1. From Emergency Department (J.W.P., M.P.T.), and Cardiology Department (S.A.), Christchurch Hospital, Christchurch, New Zealand; Department of Medicine, University of Otago, Christchurch, New Zealand (J.W.P.); Department of Emergency Medicine, Royal Brisbane and Women’s Hospital, The University of Queensland and School of Public Health, Queensland University of Technology, Brisbane, Australia (J.H.G., L.C., D.F.); Department of Cardiology, Royal Brisbane and Women’s Hospital, Brisbane, Australia (W.P...

Abstract

Background: The new European Society of Cardiology guidelines to rule-in and rule-out acute myocardial infarction (AMI) in the emergency department include a rapid assessment algorithm based on high-sensitivity cardiac troponin and sampling at 0 and 1 hour. Emergency department physicians require high sensitivity to confidently rule-out AMI, whereas cardiologists aim to minimize false-positive results. Methods: High-sensitivity troponin I and T assays were used to measure troponin concentrations in patients presenting with chest-pain symptoms and being investigated for possible acute coronary syndrome at hospitals in New Zealand, Australia, and Canada. AMI outcomes were independently adjudicated by at least 2 physicians. The European Society of Cardiology algorithm performance with each assay was assessed by the sensitivity and proportion with AMI ruled out and the positive predictive value and proportion ruled-in. Results: There were 2222 patients with serial high-sensitivity troponin T and high-sensitivity troponin I measurements. The high-sensitivity troponin T algorithm ruled out 1425 (64.1%) with a sensitivity of 97.1% (95% confidence interval [CI], 94.0%–98.8%) and ruled-in 292 (13.1%) with a positive predictive value of 63.4% (95% CI, 57.5%–68.9%). The high-sensitivity troponin I algorithm ruled out 1205 (54.2%) with a sensitivity of 98.8% (95% CI, 96.4%–99.7%)) and ruled-in 310 (14.0%) with a positive predictive value of 68.1% (95% CI, 62.6%–73.2%). Conclusions: The sensitivity of the European Society of Cardiology rapid assessment 0-/1-hour algorithm to rule-out AMI with high-sensitivity troponin may be insufficient for some emergency department physicians to confidently send patients home. These algorithms may prove useful to identify patients requiring expedited management. However, the positive predictive value was modest for both algorithms.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3