Myocardial Strain Analysis in Acute Coronary Occlusion

Author:

Lyseggen Erik1,Skulstad Helge1,Helle-Valle Thomas1,Vartdal Trond1,Urheim Stig1,Rabben Stein Inge1,Opdahl Anders1,Ihlen Halfdan1,Smiseth Otto A.1

Affiliation:

1. From the Institute for Surgical Research and Department of Cardiology, Rikshospitalet University Hospital, Oslo, Norway.

Abstract

Background— This study proposes 2 new echocardiographic indices with potential application in acute coronary artery occlusion to differentiate between viable and necrotic myocardium and to identify reperfusion. We investigated whether the ratio between systolic lengthening and combined late and postsystolic shortening (L-S ratio) could identify viable myocardium and whether systolic myocardial compliance, calculated as systolic lengthening divided by systolic pressure rise, could identify necrotic myocardium. Methods and Results— In anesthetized dogs, we measured left ventricular (LV) pressure and long-axis strain by Doppler echocardiography (SDE) and sonomicrometry. The left anterior descending coronary artery was occluded for 15 minutes with 3-hour reperfusion (n=6), for 4 hours with 3-hour reperfusion (n=6), or for 4 hours with no reperfusion (n=6). Myocardial work was quantified by pressure–segment length analysis, necrosis by triphenyltetrazolium chloride staining, and edema by water content. L-S ratio and systolic compliance were calculated by SDE. The L-S ratio ranged between 0.00 and 1.00 and was well correlated with regional myocardial work ( r =0.77, P <0.0001). In entirely passive myocardium, the L-S ratio approached 1 and was similar in viable (0.88±0.02) and necrotic (0.81±0.03) myocardium. Compliance, however, was reduced in necrotic myocardium owing to edema (0.07±0.01%/mm Hg) but was preserved in viable myocardium (0.15±0.01%/mm Hg, P <0.05). Reperfusion of viable myocardium caused a reduction of the L-S ratio after 15 minutes (0.57±0.06, P <0.05), reflecting recovery of function. Reperfusion of necrotic myocardium caused no change in the L-S ratio, but compliance was further reduced within 15 minutes (0.03±0.01%/mm Hg, P <0.05). Conclusion— Myocardial L-S ratio and compliance by SDE identified active contraction and necrosis, respectively. These indices should be tested clinically for assessment of myocardial viability and reperfusion.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 82 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3