Prediction of Cardiac Stability After Weaning From Left Ventricular Assist Devices in Patients With Idiopathic Dilated Cardiomyopathy

Author:

Dandel Michael1,Weng Yuguo1,Siniawski Henryk1,Potapov Evgenij1,Drews Thorsten1,Lehmkuhl Hans B.1,Knosalla Christoph1,Hetzer Roland1

Affiliation:

1. From the Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum, Berlin, Germany.

Abstract

Background— During ventricular assist device (VAD) unloading, cardiac recovery is possible even in patients with chronic heart failure (HF). We sought parameters predictive of cardiac stability after VAD removal. Methods and Results— Among 81 patients weaned since March 1995, a homogenous group of 35 with idiopathic dilated cardiomyopathy weaned from left VADs was selected. We evaluated echo data obtained before left VAD implantation and during “off-pump” trials before explantation, histological changes, and serum anti-β1-adrenoceptor-autoantibody disappearance during unloading, duration of unloading, and HF duration. Postweaning 10-year survival with native hearts reached 70.7±9.2%. During the first 5 years, HF recurred in 13 patients (37.1%). Only 6 (17.1%) died after HF recurrence or noncardiac complications related to left VAD explantation. Comparison of patients with and without long-term cardiac stability showed that stable patients were younger, HF history and recovery time during unloading shorter, and preweaning left ventricular assessment revealed higher left ventricular ejection fraction, lower short/long axis ratios, and higher end diastolic relative wall thicknesses. For left ventricular ejection fraction ≥45% at end diastolic diameter of ≤55 mm, predictive value for ≥5-year cardiac stability was 87.5%. Left ventricular ejection fraction time course during the first 6 postweaning months appeared predictive for long-term stability. HF history >5 years and preweaning instability of cardiac improvement appeared predictive for HF recurrence. Conclusions— In idiopathic dilated cardiomyopathy, left VAD removal can be successful for >12 years even with incomplete cardiac recovery. Pre-explantation left ventricular ejection fraction, left ventricular end diastolic diameter and relative wall thicknesses, stability of unloading-induced cardiac recovery, duration of left VAD support, and HF duration before left VAD insertion allow identification of patients able to remain stable for >5 years. Time course of left ventricular ejection fraction during the first 6 postweaning months allows prognostic assessment.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference21 articles.

1. Torre-Amione G Loebe M. Myocardial recovery following prolonged mechanical support. In: Frazier OH Kirklin JK eds. ISHLT Monograph Series. Mechanical Circulatory Support Vol 1 . New York: Elsevier; 2006: 155–169.

2. Improved Left Ventricular Function After Chronic Left Ventricular Unloading

3. When to discontinue extracorporeal membrane oxygenation for postcardiotomy support

4. Long-term follow-up of thoratec ventricular assist device bridge-to-recovery patients successfully removed from support after recovery of ventricular function

Cited by 149 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3