Comparison of activation during ventricular fibrillation and following unsuccessful defibrillation shocks in open-chest dogs.

Author:

Chen P S1,Wolf P D1,Melnick S D1,Danieley N D1,Smith W M1,Ideker R E1

Affiliation:

1. Department of Medicine, Duke University Medical Center, Durham, NC 27710.

Abstract

The purpose of this study was to map in detail the spread of activation away from sites of early postshock excitation following unsuccessful defibrillation to determine whether these activation fronts are the unaltered continuation of activation fronts present just before the shock. We recorded simultaneously from 120 bipolar electrodes on 40 plunge needles in a 20 x 35 x 5-mm volume of tissue of the right ventricular outflow tract immediately before and after shocks of 190-350 V were given via electrodes on the right atrium and left ventricular apex to six open-chest dogs with electrically induced ventricular fibrillation. For 20 shocks approximately 100 V below the defibrillation threshold, the site of earliest recorded activation following the shock was near the center of the mapped region. At the earliest recorded activation sites, there was an isoelectric window in the immediate postshock period lasting 42 +/- 15 msec after which activation fronts either spread away from a site in all directions in a focal pattern (12 episodes) or else spread away in only one direction (eight episodes). Comparison of activation patterns immediately before and after the shock revealed that in 18 of the 20 episodes, the location and pathway of activation fronts after the shock were markedly different from those before the shock. The preshock intervals at the sites of earliest activation following the shock, that is, the interval between the last activation at the site and the time of the shock, were not randomly distributed but were similar, averaging 64 +/- 11 msec, and were negatively correlated with the isoelectric postshock window (r = -0.70, p = 0.0001). These findings indicate that the presence and the site of origin of activation fronts after the shock are influenced by at least two factors: the shock itself and the electrophysiological state of the myocardium at the time of the shock. Thus, epicardial shocks approximately 100 V below the defibrillation threshold markedly alter the activation sequences of fibrillation but are unsuccessful because the activation fronts following the shock reinitiate fibrillation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Physiology

Cited by 115 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3