Improved Automated Detection of Embolic Signals Using a Novel Frequency Filtering Approach

Author:

Markus Hugh1,Cullinane Marisa1,Reid Greg1

Affiliation:

1. From the Department of Clinical Neurosciences, Guy’s King’s and St Thomas’ School of Medicine and the Institute of Psychiatry, London, England (H.M., M.C.), and Nicolet-EME GmbH (G.R.), Germany.

Abstract

Background and Purpose —Asymptomatic embolic signal detection with the use of Doppler ultrasound has a number of potential clinical applications. However, its more widespread clinical use is severely limited by the lack of a reliable automated detection system. Design of such a system depends on accurate characterization of the unique features of embolic signals, which allow their differentiation from artifact and background Doppler speckle. We used a processing system with high temporal resolution to describe these features. We then used this information to design a new automated detection system. Methods —We used a signal processing approach based on multiple overlapping band-pass filters to characterize 100 consecutive embolic signals from patients with carotid artery disease as well as both episodes of artifact resulting from probe tapping and facial movement and episodes of Doppler speckle. We then designed an automated detection system based both on these embolic signal characteristics and on the fact that embolic signals have maximum intensity over a narrow frequency range. This system was tested in real time on stored 5-second segments of data. Results —The value of peak velocity at maximal intensity discriminated best between embolic signals and artifact and allowed differentiation with 100% sensitivity and specificity. Relative intensity increase, intensity volume, area under volume, average rise rate, and average fall rate appeared to discriminate best between embolic signals and Doppler speckle. For the majority of embolic signals, the intensity increase was spread over a narrow frequency or velocity range. The automated system we developed detected 296 of 325 carotid stenosis embolic signals from a new data set (sensitivity, 91.1%). All 200 episodes of artifact from a new data set were differentiated from embolic signals. Only 2 of 100 episodes of speckle were misidentified as embolic signals. Conclusions —Using a novel system for automated detection, which utilizes the fact that embolic signals have maximum intensity over a narrow frequency range, we have achieved detection with a high sensitivity and high specificity. These results are considerably better than those previously reported. We tested this initial system on short 5-second segments of data played in real time. This approach now needs to be developed for use in a true online system to determine whether it has sufficient sensitivity and specificity for clinical use.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

Reference11 articles.

Cited by 26 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3