Intravascular Source of Adenosine During Forearm Ischemia in Humans

Author:

Costa Fernando1,Sulur Paulgun1,Angel Mark1,Cavalcante José1,Haile Virginia1,Christman Brian1,Biaggioni Italo1

Affiliation:

1. From the Division of Clinical Pharmacology, Departments of Medicine and Pharmacology, Vanderbilt University, Nashville, Tenn.

Abstract

Abstract —It is believed that adenosine is released in ischemic tissues and contributes to reactive hyperemia. We tested this hypothesis in the human forearm using microdialysis to estimate interstitial and intravascular levels of adenosine and caffeine withdrawal to potentiate endogenous adenosine and determine its effect on reactive hyperemia. Forearm blood flow response to ischemia was measured by air plethysmography before and 60 hours after the last dose of caffeine (250 mg TID for 7 days, n=6). Forearm blood flow increased by 274±66% and 467±97% after 3 minutes of forearm ischemia, before and during caffeine withdrawal, respectively ( P <0.05). Thus, caffeine withdrawal enhances reactive hyperemia. To determine the source of adenosine, we measured interstitial adenosine with the use of a microdialysis probe inserted into the flexor digitorum superficialis muscle of the forearm, and we measured intravascular adenosine with the use of a microdialysis probe inserted retrogradely into the medial cubital vein. Dialysate samples were collected at 15-minute intervals during resting, forearm ischemia, and recovery periods. Forearm ischemia failed to increase muscle dialysate concentrations of adenosine but did increase intravascular dialysate adenosine 2.1-fold, from 0.61±0.12 to 1.28±0.39 μmol/L ( P <0.01, n=8). Intravascular dialysate concentrations of thromboxane B 2 did not increase during ischemia, ruling out platelet aggregation as a source of adenosine. These results support the hypothesis that endogenous adenosine contributes to reactive hyperemia and indicate that the major source of adenosine in the human forearm is intravascular. We speculate that endothelial cells are the source of intravascular adenosine during ischemia.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3