Quantification of Alterations in Structure and Function of Elastin in the Arterial Media

Author:

Avolio Alberto1,Jones Deanna1,Tafazzoli-Shadpour Mohammad1

Affiliation:

1. From the Graduate School of Biomedical Engineering, University of New South Wales, Sydney, Australia.

Abstract

Abstract —The structure of medial elastin determines arterial function and affects wall mechanical properties. The aim of this study was to (1) characterize the structure of elastin in terms of textural features, (2) relate structural parameters to total number of cardiac cycles (TC), and (3) determine the contribution of medial elastin to lumen mechanical stress. Images of pressure-fixed aortic sections stained for elastin were obtained from specimens collected postmortem from 35 animals of different species with a wide range of age, heart rate, and TC and divided into 2 groups: TC low =3.69±0.38×10 8 (n=17) and TC high =15.8±2.38×10 8 (n=18) ( P <0.001). A directional fractal curve was generated for each image, and image texture was characterized by directional fractal curve parameters. Elastin volume fraction and interlamellar distance were obtained by image analysis. Wall stress distribution was determined from a finite element model of the arterial wall with multiple layers simulating elastin lamellae. DFC amplitude was related to elastin volume fraction. Increased TC (TC low versus TC high ) was associated with lower directional fractal curve amplitude (0.23±0.02 versus 0.14±0.02; P <0.001), reduced elastin volume fraction (36.5±2.6% versus 25.7±2.1%; P <0.01), and increased interlamellar distance (8.5±0.5 versus 11.5±1.0 μm; P <0.05). Loss of medial elastic function increased pressure-dependent maximal circumferential stress. Structural alterations of medial elastin, quantified by fractal parameters, are associated with cumulative effects of repeated pulsations due to the combined contribution of age and heart rate. Loss of medial functional elasticity increases luminal wall stress, increasing the possibility of endothelial damage and predisposition to atherosclerosis.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Internal Medicine

Reference24 articles.

1. Evolution of Elastin Structure

2. Nichols WW O’Rourke MF. McDonald’s Blood Flow in Arteries . London UK: Arnold; 1998.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3