Intravascular ultrasound assessment of lumen size and wall morphology in normal subjects and patients with coronary artery disease.

Author:

Nissen S E1,Gurley J C1,Grines C L1,Booth D C1,McClure R1,Berk M1,Fischer C1,DeMaria A N1

Affiliation:

1. Division of Cardiovascular Medicine, University of Kentucky Medical Center, Lexington 40536-0084.

Abstract

BACKGROUND Necropsy studies demonstrate that coronary artery disease (CAD) is frequently complex and eccentric. However, angiography provides only a silhouette of the vessel lumen. Intravascular ultrasound is a new tomographic imaging method for evaluation of coronary dimensions and wall morphology. Few data exist regarding intravascular ultrasound in patients with CAD, and no data exist for subjects with normal coronaries. METHODS AND RESULTS We used a multielement 5.5F, 20-MHz ultrasound catheter to examine eight normal subjects and 43 patients with CAD. We assessed the safety of coronary ultrasound and the effect of vessel eccentricity on comparison of minimum luminal diameter by angiography and ultrasound. Normal and atherosclerotic wall morphology and stenosis severity were also evaluated by intravascular ultrasound. The only untoward effect was transient coronary spasm in five patients. At 33 sites in normal subjects, the lumen was nearly circular, yielding a close correlation between angiographic and ultrasonic minimum diameter (r = 0.92). At 90 sites in patients with CAD, ultrasound demonstrated a concentric cross section; correlation was also close (r = 0.93). However, at 72 eccentric sites, correlation was not as close (r = 0.77). For 41 stenoses, correlation between angiography and ultrasound for area reduction was moderate (r = 0.63). In normal subjects, wall morphology revealed a thin (0.30 mm or less) intimal leading edge and subadjacent sonolucent zone (0.20 mm or less). Patients with CAD exhibited increased thickness and echogenicity of the leading edge, thickened sonolucent zones, and/or attenuation of ultrasound transmission. CONCLUSIONS These data establish that intravascular ultrasound is feasible and safe and yields luminal measurements that correlate generally with angiography. Differences between angiographic and ultrasound measures of lumen size in eccentric vessels probably reflect the dissimilar perspectives of tomographic and silhouette imaging techniques. Intravascular ultrasound provides detailed images of normal and abnormal wall morphology not previously possible in vivo.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference23 articles.

1. The accuracy of arteriography and ultrasound imaging for atherosclerosis measurement: A review;Blankenhorn DH;Arch Pathol Lab Med,1982

2. Quantitation of coronary arterial narrowing at necropsy in sudden coronary death

3. Correlation of the Antemortem Coronary Arteriogram and the Postmortem Specimen

4. Interobserver variability in coronary angiography.

Cited by 605 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3