Radiofrequency catheter ablation of atrial arrhythmias. Results and mechanisms.

Author:

Lesh M D1,Van Hare G F1,Epstein L M1,Fitzpatrick A P1,Scheinman M M1,Lee R J1,Kwasman M A1,Grogin H R1,Griffin J C1

Affiliation:

1. Department of Medicine, University of California, San Francisco 94143-1354.

Abstract

BACKGROUND Radio frequency catheter ablation is accepted therapy for patients with paroxysmal supraventricular tachycardia and has a low rate of complications. For patients with atrial arrhythmias, catheter ablation of the His bundle has been an option when drugs fail or produce untoward side effects. Although preventing rapid ventricular response, this procedure requires a permanent pacemaker and does not restore the atrium to normal rhythm. Therefore, we evaluated the safety and efficacy of radiofrequency ablation directed at the atrial substrate. METHODS AND RESULTS Thirty-seven patients with 42 atrial arrhythmias (mean +/- SD age, 41 +/- 24 years) who had failed a median of three drugs were enrolled. Diagnoses were automatic atrial tachycardia in 12, atypical atrial flutter in 1, typical atrial flutter in 18, reentrant atrial tachycardia in 8, and sinus node reentry in 3 patients. Sites for atrial flutter ablation were based on anatomic barriers in the floor of the right atrium. For automatic atrial tachycardia, the site of earliest activation before the P wave was sought. All with reentrant atrial tachycardia had previous surgery for congenital heart disease and reentry around a surgical scar, anatomic defect, or atriotomy incision and our goal was to identify a site of early activation in a zone of slow conduction. At target sites, 20 to 50 W of radiofrequency energy was delivered during tachycardia between the 4- or 5-mm catheter tip and a skin patch, except in 4 patients with atrial flutter, in whom a catheter with a 10-mm thermistor-embedded tip was used. Procedure end point was inability to reinduce tachycardia. Acute success was achieved in 11 of 12 (92%) with automatic atrial tachycardia, 17 of 18 (94%) with typical atrial flutter, 7 of 8 (88%) with reentrant atrial tachycardia, and 3 of 3 (100%) with sinus node reentry but not in the patient with atypical atrial flutter. For tachycardia involving reentry (reentrant atrial tachycardia and atrial flutter), successful ablation required severing an isthmus of slow conduction. For those with atrial flutter, this was between the tricuspid annulus and the coronary sinus os (10) or posterior (4) or posterolateral (3) between the inferior vena cava (2) or an atriotomy scar (1) and the tricuspid annulus. Deep venous thrombosis occurred in 1 patient. At mean follow-up of 290 +/- 40 days, the ablated arrhythmia recurred in 1 (9%) with automatic atrial tachycardia, 5 (29%) with atrial flutter, and 1 (14%) with reentrant atrial tachycardia, all of whom had successful repeat ablation. Previously undetected arrhythmias occurred in 2 patients who are either asymptomatic or controlled with medication. CONCLUSIONS Ablation of automatic and reentrant atrial tachycardia and atrial flutter had a high success rate and caused no complications from energy application. Repeat procedures may be required for long-term success, especially in patients with atrial flutter. The mechanism by which ablation is successful is similar for atrial flutter and other forms of atrial reentry and involves severing a critical isthmus of slow conduction bounded by anatomic or structural obstacles. Automatic arrhythmias are abolished by directing lesions at the focus of abnormal impulse formation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3