Histopathologic validation of angioscopy and intravascular ultrasound.

Author:

Siegel R J1,Ariani M1,Fishbein M C1,Chae J S1,Park J C1,Maurer G1,Forrester J S1

Affiliation:

1. Division of Cardiology, Cedars-Sinai Medical Center, Los Angeles, CA 90048-0750.

Abstract

BACKGROUND To establish a histopathologic basis for angioscopic and ultrasound image interpretation we studied 70 postmortem human arterial segments in vitro. METHODS AND RESULTS We used 7- to 9-French fiber-optic angioscopes and 20- to 30-MHz intravascular ultrasound imaging catheters. Three observers assigned an angioscopic and ultrasound image classification to each vessel segment. The image and histological classification categories were then compared. The sensitivity, specificity, and accuracy of both methods separately or in combination for normal vessels were each greater than or equal to 95%. The predictive value was better for angioscopy than for ultrasound due to incorrect ultrasound interpretations of normal anatomy in the presence of thrombus. For stable atheroma the sensitivity, specificity, and accuracy of the individual methods were each greater than 90%. However, both angioscopy and ultrasound had classification errors in that disrupted atheroma was identified and classified as stable atheroma. Consequently, the predictive value was 74% for angioscopy and 78% for ultrasound. For disrupted atheroma the sensitivities for angioscopy and ultrasound were only moderate (73% and 81%, respectively), whereas the specificity, accuracy, and predictive value were each high (greater than 90%). For thrombus detection, the specificity, accuracy, and predictive value were high (greater than 93%) for each method. The sensitivity of angioscopy was 100%. However, sensitivity was lower for ultrasound (57%) due to false-negative interpretation of laminar clots in normal vessels and an inability to distinguish disrupted or stable atheroma from intraluminal thrombus. CONCLUSIONS Contingency analyses showed that each imaging method alone or combined had significant agreement with the results obtained from histology (p less than 0.001). When assessing all cases in which angioscopy and ultrasound were concordant, there was a 92% agreement with the histological classification.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference24 articles.

1. Coronary Angioscopy in Patients with Unstable Angina Pectoris

2. Two-dimensional intravascular ultrasound technical development and initial clinical experience;Yock PG;J Am Soc Echo,1989

3. Comparative Studies of Angioscopy and Ultrasound for the Evaluation of Arterial Disease

4. The Pathogenesis of Atherosclerosis

Cited by 197 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3