Technetium-99m hexakis 2-methoxy-2-isobutyl isonitrile and thallium-201 extraction, washout, and retention at varying coronary flow rates in rabbit heart.

Author:

Marshall R C1,Leidholdt E M1,Zhang D Y1,Barnett C A1

Affiliation:

1. Cardiology Section, Veterans Affairs Medical Center, Martinez, Calif. 94553.

Abstract

Technetium-99m hexakis 2-methoxy-2-isobutyl isonitrile (Tc-MIBI) and thallium-201 extraction, washout, and retention were investigated and compared in 20 isolated, isovolumic, retrograde blood-perfused rabbit hearts at flow rates ranging from 0.5 to 3.5 ml/g wet wt min-1 in the absence of tracer recirculation. Mean Tc-MIBI peak instantaneous extraction was lower (0.55 +/- 0.10, p less than 0.001) and more affected by flow rate (p less than 0.05) than 201Tl peak instantaneous extraction (0.83 +/- 0.06). In contrast, the rate of 201Tl washout was significantly faster (p less than 0.05) and initially more dependent on perfusion rate (p less than 0.05) than Tc-MIBI washout. Reflecting its higher peak instantaneous extraction, 201Tl retention was 55-79% higher immediately after isotope injection (p less than 0.001) than Tc-MIBI retention, and relative changes in maximal 201Tl net uptake correlated better (p less than 0.05) with relative flow changes than maximal Tc-MIBI net uptake. However, due to its faster washout rate, the superiority of thallium over Tc-MIBI as a perfusion indicator was lost within 10 minutes of tracer injection under the present single-pass experimental conditions. These data were interpreted to indicate that 1) Tc-MIBI is not as well extracted and has a slower washout rate than 201Tl; 2) varying the coronary flow rate has significant but divergent effects on the extraction, washout, and retention of Tc-MIBI and 201Tl; and 3) the present results support continued evaluation of Tc-MIBI as a possible perfusion indicator.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference20 articles.

1. Technetium-99m hexakis 2-methoxyisobutyl isonitrile: Human biodistribution, dosimetry, safety, and preliminary comparison to thallium-201 for myocardial perfusion imaging;Wackers FJT;J Nucl Med,1989

2. Technetium-99m methoxyisobutyl isonitrile (RP30) for quantification of myocardial ischemia and reperfusion in dogs;Li QS;J Nuci Med,1988

3. Hexakis (2-methoxy isobutylisonitrile) technetium-99m and thallium-201 chloride: Uptake and release in cultured myocardial cells;Maublant JC;J Nucl Med,1988

4. Hexakis (carbomethoxyisopropylisonitrile) technetium(I), a new myocardial perfusion imaging agent: Binding characteristics in cultured chick cells;Piwnica-Worms D;J Nucl Med,1988