Quantification and validation of left ventricular wall thickening by a three-dimensional volume element magnetic resonance imaging approach.

Author:

Beyar R1,Shapiro E P1,Graves W L1,Rogers W J1,Guier W H1,Carey G A1,Soulen R L1,Zerhouni E A1,Weisfeldt M L1,Weiss J L1

Affiliation:

1. Department of Medicine, Johns Hopkins Medical Institutions, Baltimore, Maryland 21205.

Abstract

We have developed a method to quantify and map regional wall thickening throughout the left ventricle (LV) with magnetic resonance imaging. In contrast to methods that measure planar wall thickness and thickening, this method uses the three-dimensional (3D) geometry of the left ventricle to calculate the perpendicular thickness of the wall. We tested this method at three levels of increasing complexity using 1) phantom studies, 2) in vivo experiments in dogs with normal cardiac function, and 3) in vivo studies in dogs during acute ischemia. Experiments were conducted in 15 open-chest dogs imaged by a 0.38 T iron core magnet. Five short-axis images at end diastole and end systole were obtained with the spin echo technique by use of the QRS as a trigger for end diastole and the second heart sound, S2, to time end systole. After acquisition of preischemic images, acute ischemia was induced by either coronary artery ligation (n = 5) or intracoronary dental rubber injection (n = 5), which produced severe transmural ischemia. By use of computer-aided contouring of the endocardial and epicardial borders, each image was divided into 16 segments with radial lines originating from the midwall centroid. A 3D volume element was defined as that generated by connecting two matched planar segments in two adjacent image planes. This defined 64 volume elements comprising the entire left ventricle. Thickness and thickening before and during ischemia were then calculated by using the planar segments and the 3D volume elements. In phantom studies, the 3D method was accurate, independent of the angle of inclination of the image plane to the phantom wall, whereas the planar method showed considerable overestimation of thickness when the image plane was oblique to the phantom wall. In the dogs before induction of ischemia, the 3D method demonstrated the well-established normal taper in end-diastolic wall thickness from 1.10 +/- 0.02 cm at the base to 1.05 +/- 0.11 cm at the apex (p less than 0.01). By contrast, the planar method did not detect the decrease in thickness toward the apex (1.13 +/- 0.07 cm at the base vs. 1.16 +/- 0.14 cm at the apex, p = NS). During acute ischemia, thickening was calculated by both methods at the center of the ischemic zone defined by Monastral blue nonstaining and compared with the preischemic values.(ABSTRACT TRUNCATED AT 400 WORDS)

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3