Quantification of left-to-right atrial shunting and defect size after balloon mitral commissurotomy using biplane transesophageal echocardiography, color flow Doppler mapping, and the principle of proximal flow convergence.

Author:

Rittoo D1,Sutherland G R1,Shaw T R1

Affiliation:

1. Department of Cardiology, Western General Hospital, Edinburgh, UK.

Abstract

BACKGROUND The flow convergence region (FCR), a zone of progressive laminar velocity acceleration, can be imaged by color Doppler proximal to stenotic and regurgitant orifices. Theoretically, FCR proximal to a discrete circular and planar orifice consists of concentric hemispheric shells of equal and accelerating velocities centered at the orifice. According to the continuity principle, flow rate across any of these isovelocity surfaces equals flow rate through the orifice. The aim of this study was to investigate whether these principles could be applied to quantify left-to-right shunting and the size of atrial septal defects after balloon mitral commissurotomy. METHODS AND RESULTS Biplane transesophageal echocardiography (TEE) with color flow imaging was performed on 36 consecutive patients (mean age, 57 +/- 16 years; range, 14-78 years) immediately before and within 24 hours of balloon (Inoue, n = 33; Mansfield, n = 3) mitral commissurotomy. Left-to-right atrial shunting was detected by TEE in 33 patients (92%) and by oximetry in 11 patients (31%). The radius r of FCR was measured from the first aliasing limit, at a Nyquist velocity reduced to 11 cm/sec by zero-shifting, to the orifice in the atrial septum. FCR was assumed to be hemispherical. Hence, flow rate (Q) was calculated as 2 pi r2 Vr, where Vr is the velocity at a radial distance r. The velocity profile of transatrial flow was assessed by means of high pulse repetition frequency, from which the maximum flow velocity (Vp) and the velocity-time integral (VTI) were obtained. The flow area of the atrial septal defect was calculated as Qm, the maximal flow rate, divided by Vp. Hence, shunt flow was calculated as flow area x VTI x heart rate. FCR was analyzed in two orthogonal planes. Mean Qm (38.1 +/- 26.5 versus 5.3 +/- 2.7 mL/sec), flow area (22.1 +/- 11.2 versus 4.4 +/- 2.0 mm2), and shunt flow (1,590 +/- 1,070 versus 200 +/- 130 mL/min) on transverse plane imaging were all significantly higher in patients with shunts detected by oximetry than in those without. Similar results were obtained from longitudinal plane imaging. Qm correlated well with oximetric shunt flow (r = 0.89-0.94, p < 0.001) and shunt ratio (r = 0.91-0.94, p < 0.001). Flow area correlated closely (r = 0.93-0.94, p < 0.001) with area determined by direct measurement from two-dimensional echocardiography. Shunt flow determined by FCR also correlated closely (r = 0.94-0.98, p < 0.001) with that determined by oximetry and that derived from two-dimensional echocardiography and pulsed Doppler (r = 0.96, p < 0.001). CONCLUSIONS The flow convergence region imaged by TEE color flow mapping provides new and accurate quantitative information on atrial shunt flow and defect size after balloon mitral valvotomy. It is a quick, reliable, and fairly simple method that can be readily incorporated into routine clinical practice.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 28 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3