Mitral valve replacement with and without chordal preservation in patients with chronic mitral regurgitation. Mechanisms for differences in postoperative ejection performance.

Author:

Rozich J D1,Carabello B A1,Usher B W1,Kratz J M1,Bell A E1,Zile M R1

Affiliation:

1. Department of Medicine, Medical University of South Carolina, Charleston 29525.

Abstract

BACKGROUND Standard mitral valve replacement (MVR) in patients with chronic mitral regurgitation consistently results in a decrease in postoperative left ventricular (LV) ejection performance. This fall in ejection performance has been attributed, at least in part, to unfavorable loading conditions imposed by the elimination of the low-impedance pathway for LV emptying into the left atrium. In contrast to standard MVR in which the chordae tendineae are severed, however, MVR with chordal preservation (MVR-CP) does not usually decrease LV ejection performance despite similar removal of the low-impedance pathway. The purpose of the present study was to define the mechanisms responsible for this discordance in postoperative ejection performance between MVR with and without chordal preservation. METHODS AND RESULTS Echocardiography and sphygmomanometer blood pressures were obtained in 15 patients with pure chronic mitral regurgitation before and 7-10 days after mitral valve surgery. These measurements were used to calculate ventricular volume, wall stress, and ejection fraction. Seven patients underwent MVR with chordal transection (MVR-CT), and eight patients underwent MVR-CP. MVR-CT resulted in no postoperative change in LV end-diastolic volume, a significant increase in LV end-systolic volume, a significant increase in end-systolic stress, from 89 +/- 9 to 111 +/- 12 g/cm2 (p < 0.05), and a significant decrease in ejection fraction, from 0.60 +/- 0.02 to 36 +/- 0.02 (p < 0.05). In contrast, patients who underwent MVR-CP had a significant decrease in LV end-diastolic and end-systolic volumes. End-systolic wall stress actually fell from 95 +/- 6 to 66 +/- 6 g/cm2 (p < 0.05), and ejection fraction was unchanged (0.63 +/- 0.01 before and 0.61 +/- 0.02 after mitral valve surgery) instead of reduced. CONCLUSIONS MVR-CT resulted in a decrease in ejection performance caused in part by an increase in end-systolic stress, which in turn increased end-systolic volume. Conversely, MVR-CP resulted in a smaller LV size, allowing a reduced end-systolic stress and preservation of ejection performance despite closure of the low-impedance left atrial ejection pathway.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 203 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3