Mechanism of cardiac defibrillation in open-chest dogs with unipolar DC-coupled simultaneous activation and shock potential recordings.

Author:

Witkowski F X1,Penkoske P A1,Plonsey R1

Affiliation:

1. Department of Medicine, University of Alberta School of Medicine, Edmonton, Canada.

Abstract

The automatic implantable cardioverter-defibrillator has been shown to dramatically improve survival. The future refinement of these devices requires a clear understanding of their mechanism of action. We performed the following study to test two hypotheses: 1) When defibrillation is successful, fibrillating activity must be annihilated in a critical mass of both ventricles; and 2) when defibrillation is unsuccessful, at least one area of the ventricular mass has been left fibrillating. Unipolar Ag/AgCl sintered electrodes were directly coupled from triangular arrays at 40 epicardial locations (total, 120 recording sites) that covered both right and left ventricular surfaces and were designed to measure the voltage gradient generated by the shock at each triangular array as well as the underlying myocardial electrical activity before and immediately after the shock. An algorithm was developed and tested that reliably scored whether a postshock activation was a continuation of the immediately previous fibrillating activity. This technique was applied to 203 defibrillation attempts in six open-chest dogs during electrically induced ventricular fibrillation. There were 139 successful defibrillation attempts and 64 unsuccessful attempts. Monophasic truncated exponential 10-msec defibrillation shocks (0.5-35 J) were delivered through an anodal patch on the right atrium and a cathodal patch on the left ventricular apex. In all cases of unsuccessful defibrillation, at least one ventricular site could be clearly identified that failed to be defibrillated. In cases of successful defibrillation two distinct patterns were observed: 1) complete annihilation of fibrillating activity at all sites or 2) nearly complete cessation of fibrillating activity with a single area of persistent fibrillation that subsequently self-extinguished within one to three activations. This single site in the second form of successful defibrillation was located in the region of minimum voltage gradient produced by the defibrillating waveform and was occasionally accompanied by dynamic encapsulation with refractory tissue as a result of a wavefront emanating from a region that had undergone successful defibrillation. These results support the hypothesis that a critical mass of myocardium must be affected for successful defibrillation and that unsuccessful defibrillation is always accompanied by residual fibrillating activity in at least one site. The results also demonstrate that the size of the critical mass required for successful defibrillation can be less than 100%.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 147 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3