Assessment of the immediate effects of cardiopulmonary bypass on left ventricular performance by on-line pressure-area relations.

Author:

Gorcsan J1,Gasior T A1,Mandarino W A1,Deneault L G1,Hattler B G1,Pinsky M R1

Affiliation:

1. University of Pittsburgh Medical Center, PA 15261.

Abstract

BACKGROUND Pressure-volume relations have been established as useful measures of left ventricular (LV) performance. Application of these methods to the intraoperative setting have been limited because of difficulties acquiring LV volume data. Transesophageal echocardiographic automated border detection can measure LV cross-sectional area as an index of volume, which can be coupled with pressure data to construct pressure-area loops on-line. The purpose of this study was to evaluate intraoperative LV performance in patients undergoing coronary bypass surgery before and immediately after cardiopulmonary bypass using on-line pressure-area relations. METHODS AND RESULTS Studies were attempted in 13 consecutive patients. Simultaneous measures of LV cross-sectional area, LV pressure, and electromagnetic flow probe-derived aortic flow recorded on a computer work station interfaced with the ultrasound system. Pressure-area loops were compared with simultaneous pressure-volume loops constructed from pressure and flow data during inferior vena caval occlusions before and after bypass. Pressure-volume calculations (end-systolic elastance, maximal elastance, and preload-recruitable stroke work) were then applied to pressure-area loops with area substituted for volume data. Changes in stroke force from pressure-area loops were closely correlated with changes in estimates of stroke work from pressure-volume loops for individual patients before bypass (r = .99 +/- .03, SEE = 5 +/- 2%, n = 10) and after bypass (r = .96 +/- .05, SEE = 5 +/- 2%, n = 9). Pressure-area estimates of end-systolic elastance, maximal elastance, and preload-recruitable stroke force decreased significantly from before to after cardiopulmonary bypass in the 7 patients with paired data sets. Load-dependent measures of LV function (stroke volume, cardiac output, and fractional area change) were unchanged after surgery in these same patients. CONCLUSIONS Intraoperative pressure-area loops may be acquired and displayed on-line using transesophageal echocardiographic automated border detection and readily analyzed in a manner similar to pressure-volume loops. LV performance was depressed immediately after cardiopulmonary bypass compared with before. On-line pressure-area relations may be clinically useful to assess LV performance in patients undergoing cardiac surgery in whom load and contractility may be expected to vary rapidly.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 119 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3