Echocardiographic detection of coronary artery disease during dobutamine infusion.

Author:

Sawada S G1,Segar D S1,Ryan T1,Brown S E1,Dohan A M1,Williams R1,Fineberg N S1,Armstrong W F1,Feigenbaum H1

Affiliation:

1. Department of Medicine, Indiana University School of Medicine, Indianapolis.

Abstract

BACKGROUND Two-dimensional echocardiography performed during dobutamine infusion has been proposed as a potentially useful method for detecting coronary artery disease. However, the safety and diagnostic value of dobutamine stress echocardiography has not been established. METHODS AND RESULTS In this study, echocardiograms were recorded during step-wise infusion of dobutamine to a maximum dose of 30 micrograms/kg/min in 103 patients who also underwent quantitative coronary angiography. The echocardiograms were digitally stored and displayed in a format that allowed simultaneous analysis of rest and stress images. Development of a new abnormality in regional function was used as an early end point for the dobutamine infusion. No patient had a symptomatic arrhythmia or complications from stress-induced ischemia. Significant coronary artery disease (greater than or equal to 50% diameter stenosis) was present in 35 of 55 patients who had normal echocardiograms at rest. The sensitivity and specificity of dobutamine-induced wall motion abnormalities for coronary artery disease was 89% (31 of 35) and 85% (17 of 20), respectively. The sensitivity was 81% (17 of 21) in those with one-vessel disease and 100% (14 of 14) in those with multivessel or left main disease. Forty-one of 48 patients with abnormal echocardiograms at baseline had localized rest wall motion abnormalities. Fifteen had coronary artery disease confined to regions that had abnormal rest wall motion, and 26 had disease remote from these regions. Thirteen of 15 patients (87%) without remote disease did not develop remote stress-induced abnormalities, and 21 of 26 (81%) who had remote disease developed corresponding abnormalities. CONCLUSIONS Echocardiography combined with dobutamine infusion is a safe and accurate method for detecting coronary artery disease and for predicting the extent of disease in those who have localized rest wall motion abnormalities.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 653 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3