Validation of Renal Oxidative Metabolism Measurement by Positron-Emission Tomography

Author:

Juillard Laurent1,Lemoine Sandrine1,Janier Marc F.1,Barthez Paul Y.1,Bonnefoi Frédéric1,Laville Maurice1

Affiliation:

1. From the Département De Néphrologie (L.J., S.L., M.L.), Hôpital Edouard Herriot, Hospices Civils de Lyon, Lyon, France; ANIMAGE-Centre de Recherche Et d’Application en Traitement de l’Image et du Signal (M.F.J.), Unité mixte de Recherche-Centre National de la Recherche Scientifique 5220, Institut National de la Santé et de la Recherche Médicale U630, Hôpital Edouard Herriot, Hospices Civils de Lyon, Lyon, France; Centre D’exploration et de Recherche Médicale par Emission de Positons (M.F.J.,...

Abstract

Either in research or in clinical practice, the exploration of renal oxidative metabolism is limited by the lack of noninvasive measurement. Positron-emission tomography using carbon-11 acetate may estimate tissue oxidative metabolism by measuring acetate turnover in the Krebs cycle. Although extensively studied in cardiology, this method has never been validated for renal oxidative metabolism measurement. The aim of this study is the validation of acetate turnover compared with the invasive renal oxygen consumption measurement. Renal oxygen consumption and tubular sodium reabsorption were measured invasively in 10 anesthetized pigs. Simultaneously, acetate turnover was estimated by the clearance of carbon-11 acetate in the renal cortex, after a 166-MBq injection of carbon-11 acetate. Renal oxidative metabolism was measured under various conditions induced by mechanical and pharmacological interventions. Renal oxygen consumption and acetate turnover varied on a wide range from 0.05 to 0.29 mmol min −1 (>5-fold) and from 0.025 to 0.188 minutes −1 (>7-fold), respectively. Acetate turnover was very significantly correlated with renal oxygen consumption ( P <0.0001; R =0.82) and tubular sodium reabsorption ( P =0.001; R =0.67). This study demonstrates that acetate turnover measures renal oxidative metabolism noninvasively and quantitatively, consistent with changes in tubular sodium reabsorption. This method may be applied to assess oxidative metabolism in animal models and in humans.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3