Two arterial effective reflecting sites may appear as one to the heart.

Author:

Burattini R1,Knowlen G G1,Campbell K B1

Affiliation:

1. Department of Electronics and Automatica, University of Ancona, Italy.

Abstract

The relation between reflected waves and features of ascending aortic pressure waveforms and impedance patterns was investigated with a modified T-tube model of the systemic arterial circulation. Ascending aortic pressure and flow and descending aortic flow were measured in 10 dogs under basal conditions and under the effect of an agent (methoxamine) that caused vasoconstriction and an increase of mean aortic pressure. A broad range of aortic pressure amplitudes and features was obtained. These waveshapes were classified into four groups. Under basal conditions, cases for which a prominent diastolic fluctuation was present (n = 8) were grouped in A. Cases for which this fluctuation was absent (n = 2) were grouped in B. Groups C (n = 4) and D (n = 3) included cases that, under vasoconstricted conditions, did or did not display, respectively, a diastolic fluctuation in pressure. Arterial T-tube model parameters were estimated by simultaneously fitting the model to both ascending and descending aortic flow with aortic pressure as input. A good fit was obtained in any case considered. After parameter estimation, forward and reflected waves and impedance patterns at the entrance of head circulation (head and upper limbs) and body circulation (trunk and lower limbs) as well as their merger in the ascending aorta were determined. T-tube input impedance compared well with impedance data points obtained from the ratio of corresponding harmonics of ascending aortic pressure and flow. In some cases (group A), modulus and phase spectra displayed two distinct minima, in the range from 0 to 10 Hz. In some other circumstances, these minima were less distinct (groups B and C) and could even appear as one (group D). Whether one or two minima appeared in the ascending aortic impedance spectra at low frequency and whether a prominent diastolic fluctuation did or did not appear in aortic pressure, pressure and flow waveshapes proximal to the heart were explained by the presence of two effective reflecting sites in the systemic circulation. In group B, a diastolic fluctuation in pressure was absent despite the fact that head-end and body-end reflected waves were distinct. This happened because body-end reflected waves peaked corresponding to a minimum of the head-end reflected wave. In group D, a diastolic fluctuation in aortic pressure was absent because the body-end reflected wave moved into systole and superimposed on the head-end reflected wave. This superimposition was due to increased pulse wave velocity in the body transmission path as a result of decreased arterial distensibility.(ABSTRACT TRUNCATED AT 400 WORDS)

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Physiology

Cited by 43 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. In Vivo Validation of a Cardiovascular Simulation Model in Pigs;Mathematical and Computational Applications;2022-03-18

2. Wave reflection in the arterial tree;Textbook of Arterial Stiffness and Pulsatile Hemodynamics in Health and Disease;2022

3. Uniform tube models with single reflection site do not explain aortic wave travel and pressure wave shape;Physiological Measurement;2018-12-24

4. Distributed Models and Tube Models;Snapshots of Hemodynamics;2018-09-15

5. Aging is Associated With an Earlier Arrival of Reflected Waves Without a Distal Shift in Reflection Sites;Journal of the American Heart Association;2016-09

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3