Immediate and Long-Term Effect of Balloon Angioplasty or Stent Implantation on the Absolute and Relative Coronary Blood Flow Velocity Reserve

Author:

van Liebergen Rob A. M.1,Piek Jan J.1,Koch Karel T.1,de Winter Robbert J.1,Lie Kong I.1

Affiliation:

1. From the Department of Cardiology, Academic Medical Center, Amsterdam, Netherlands.

Abstract

Background —There is controversy regarding the immediate and long-term effects of PTCA on the coronary flow reserve. Methods and Results —A total of 54 patients with 1-vessel disease and normal left ventricular function were studied after balloon angioplasty (n=34) or stent implantation (n=20). Distal coronary blood flow velocity reserve (CFR) was defined as the ratio of adenosine-induced hyperemic versus baseline blood flow velocity with a 0.014-in Doppler guidewire. The relative CFR was defined as the ratio of the distal CFR and the reference CFR measured in the normal adjacent coronary artery. Hemodynamic and angiographic measurements were performed before and directly after balloon angioplasty or stent implantation and at 6-month follow-up. CFR after PTCA ≤2.5 was defined as an impaired CFR. Immediately after PTCA, CFR improved toward the range of the reference artery CFR. In both the balloon-treated and the stent-treated groups, initial high CFR values decreased and impaired CFR values increased at follow-up toward the values of the reference CFR in patients without restenosis. Impaired CFR after balloon angioplasty (33%) or stent implantation (58%) in patients without restenosis was related to an increased baseline flow velocity that normalized at follow-up. Patients with an increase of CFR after stenting were characterized by an unaltered baseline flow velocity and an increased adenosine-induced hyperemic flow velocity. Conclusions —An impaired CFR (≤2.5) is a frequent finding after balloon angioplasty or stent implantation as a result of a high baseline flow velocity. Normalization of impaired CFR at follow-up in patients without restenosis was associated with a decline of the baseline flow velocity after both balloon angioplasty and stent implantation, supporting the contention that this phenomenon relates to a slow recovery of autoregulation of the microvascular bed.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3