Abstract

Background —Accurate mapping of the site of origin and activation sequence of a cardiac arrhythmia is essential for a successful catheter ablation procedure. To achieve this, precise and reproducible catheter manipulation is mandatory. The aim of this study was (1) to assess the accuracy of a new nonfluoroscopic mapping system in humans and (2) to report the first result of endocardial activation mapping with this system during sinus rhythm and several types of supraventricular and ventricular tachycardias. Methods and Results —Fifteen patients were studied. Accuracy measurements were performed in 5 of them (patients 5, 6, 7, 8, and 14). The distances between two subsequent catheter positions in the inferior caval vein as determined by the nonfluoroscopic mapping system were compared with measurements made with calipers by four independent investigators using identification marks on the catheter shaft. The difference between these two methods was 0.95±0.8 mm. In 15 patients, activation of the right atrium and/or the right or left ventricle was recorded during sinus rhythm. Three-dimensional activation maps were constructed in patients with atrial and ventricular tachycardias and Wolff-Parkinson-White syndrome. Conclusions —With this new nonfluoroscopic mapping technique, accurate positioning of the catheter tip is possible. A three-dimensional activation map can be reconstructed during sinus rhythm and during supraventricular and ventricular tachycardias of different compartments of the heart.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 109 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3