Evaluation of Different Ventricular Pacing Sites in Patients With Severe Heart Failure

Author:

Blanc Jean-Jacques1,Etienne Yves1,Gilard Martine1,Mansourati Jacques1,Munier Stéphane1,Boschat Jacques1,Benditt David G.1,Lurie Keith G.1

Affiliation:

1. From the Department of Cardiology, Brest (France) University Hospital (J.-J.B., Y.E., M.G., J.M., S.M., J.B.) and the Cardiac Arrhythmia Center, University of Minnesota, Minneapolis (D.G.B., K.G.L.).

Abstract

Background Multisite ventricular pacing has recently been proposed as an additional treatment for patients with severe congestive heart failure. To further assess the potential value of this technique, we compared the acute hemodynamic changes associated with pacing the right ventricular apex (RVA) or outflow tract (RVOT) alone, the left ventricle (LV) alone, or biventricular (BIV) pacing of the RVA and LV together. Methods and Results Acute hemodynamic findings were measured in 27 patients with severe heart failure despite optimal therapy and either first-degree AV block and/or an intraventricular conduction defect. In the 23 patients with a high pulmonary capillary wedge pressure (PCWP) (>15 mm Hg), data were collected after transvenous pacing at different ventricular sites in either the VDD mode (AV delay=100 ms) or the VVI mode in patients with atrial fibrillation (n=6). The mean baseline cardiac index was 1.82 L · min −1 · m −2 . Mean±SD baseline systolic blood pressure (SBP) (118.5±15.2 mm Hg), PCWP (26.4±6.6 mm Hg), and V-wave amplitude (39.1±14.6 mm Hg) were similar before and after either RVA or RVOT pacing. In contrast, LV-based pacing (either LV alone or BIV pacing) resulted in higher SBP ( P <.03) and lower PCWP ( P <.01) and V-wave amplitude ( P <.001) than either baseline or RV pacing measurements. With LV pacing alone, SBP, PCWP, and V waves were 126.5±15.1, 20.7±5.9, and 25.5±8.1 mm Hg, respectively. The results with LV pacing alone were similar to those obtained with BIV pacing. Conclusions In patients with severe congestive heart failure, both LV pacing alone and BIV pacing resulted in a similar and significant acute improvement in SBP, PCWP, and V-wave amplitude compared with baseline measurements and RV pacing alone. These results provide a strong basis for initiating long-term studies examining the chronic effects of LV-based pacing in patients with medically refractory congestive heart failure.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 408 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Conduction System Pacing for Cardiac Resynchronization Therapy;Journal of Cardiovascular Development and Disease;2023-10-31

2. Timing Cycles;Cardiac Pacing, Defibrillation and Resynchronization;2021-04-19

3. Hemodynamics of Cardiac Pacing;Cardiac Pacing, Defibrillation and Resynchronization;2021-04-19

4. Role of coronary flow regulation and cardiac-coronary coupling in mechanical dyssynchrony associated with right ventricular pacing;American Journal of Physiology-Heart and Circulatory Physiology;2021-03-01

5. Left bundle branch area. A new site for physiological pacing: a pilot study;Heart and Vessels;2020-05-27

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3