A Novel Method for Treatment of Abdominal Aortic Aneurysms Using Percutaneous Implantation of a Newly Designed Endovascular Device

Author:

Ruiz Carlos E.1,Zhang He Ping1,Douglas Jayne T.1,Zuppan Craig W.1,Kean Charles J.C.1

Affiliation:

1. From the Division of Cardiology, Department of Medicine, and the Department of Pathology, Loma Linda University School of Medicine, Loma Linda, Calif.

Abstract

Background Percutaneous implantation of a stent to bridge abdominal aortic aneurysm (AAA) may provide an alternative to surgical reconstruction in patients with this serious disorder. We developed a self-expandable, stainless steel, woven mesh endovascular device with a delivery catheter and studied its efficacy in a canine model of AAA. Methods and Results Infrarenal AAAs were created surgically in eight adult dogs using autologous tissue. Two types of endovascular stents were used in this study: a plain or uncovered stent, about 14 mm in diameter in the unconstrained configuration, and a covered stent, coated by porous polyurethane, about 16 mm in diameter. All stents were successfully placed on the first attempt. Aortograms revealed a mean aneurysm diameter of 1.86±0.47 cm, an average of 70% larger than the reference aortic lumen before stent placement. After stent placement, aortograms showed that the aneurysmal cavity disappeared completely in three dogs treated with a covered stent and that the aortic blood flow into the cavity markedly reduced, with faint contrast filling the cavity in the remaining five dogs treated with an uncovered stent. The uncovered stent was intentionally placed across the major arterial branches in two dogs. No acute complications were encountered at the time of stent placement. Two dogs were killed shortly after the procedure for immediate evaluation of the device, which was found to be in place and patent. One dog in which a covered stent was placed was euthanized 2 \batchmode \documentclass[fleqn,10pt,legalpaper]{article} \usepackage{amssymb} \usepackage{amsfonts} \usepackage{amsmath} \pagestyle{empty} \begin{document} \(\frac{1}{2}\) \end{document} weeks later because of paraplegia secondary to a spinal cord infarction noted 48 hours after stent placement. Postmortem study revealed thrombus occluding the stent lumen. The remaining five dogs tolerated the devices well and completed 4 weeks of follow-up. Premortem aortograms showed no residual aneurysmal cavity in four dogs and only a small cavity in one dog that had received an uncovered stent. All stents were fully patent with no thrombus and were either completely or partially surfaced by neointima. Importantly, the major arterial branches over which the uncovered stents were placed were widely patent without obstruction by neointima. Conclusions This study demonstrates the feasibility of percutaneous implantation of this new device and its effectiveness in the treatment of surgically created AAA in our canine model. The covered stent was able to exclude AAA immediately upon deployment and is of potential value in the emergency treatment of leaking AAAs. The uncovered stent appears to safely bridge branch arteries as well as significantly reduce the angiographic size of the aneurysm and may be useful in the elective therapy of AAAs. These results are promising, and future clinical trials to investigate the safety and efficacy of this device in humans are warranted.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 55 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3