Repeated Administration of Vasopressin but Not Epinephrine Maintains Coronary Perfusion Pressure After Early and Late Administration During Prolonged Cardiopulmonary Resuscitation in Pigs

Author:

Wenzel Volker1,Lindner Karl H.1,Krismer Anette C.1,Miller Egfried A.1,Voelckel Wolfgang G.1,Lingnau Werner1

Affiliation:

1. From the Department of Anesthesia and Intensive Care Medicine, Leopold-Franzens-University of Innsbruck, Austria.

Abstract

Background —It is unknown whether repeated dosages of vasopressin or epinephrine given early or late during basic life support cardiopulmonary resuscitation (CPR) may be able to increase coronary perfusion pressure above a threshold between 20 and 30 mm Hg that renders defibrillation successful. Methods and Results —After 4 minutes of cardiac arrest, followed by 3 minutes of basic life support CPR, 12 animals were randomly assigned to receive, every 5 minutes, either vasopressin (early vasopressin: 0.4, 0.4, and 0.8 U/kg, respectively; n=6) or epinephrine (early epinephrine: 45, 45, and 200 μg/kg, respectively; n=6). Another 12 animals were randomly allocated after 4 minutes of cardiac arrest, followed by 8 minutes of basic life support CPR, to receive, every 5 minutes, either vasopressin (late vasopressin: 0.4 and 0.8 U/kg, respectively; n=6), or epinephrine (late epinephrine: 45 and 200 μg/kg, respectively; n=6). Defibrillation was attempted after 22 minutes of cardiac arrest. Mean±SEM coronary perfusion pressure was significantly higher 90 seconds after early vasopressin compared with early epinephrine (50±4 versus 34±3 mm Hg, P <0.02; 42±5 versus 15±3 mm Hg, P <0.0008; and 37±5 versus 11±3 mm Hg, P <0.002, respectively). Mean±SEM coronary perfusion pressure was significantly higher 90 seconds after late vasopressin compared with late epinephrine (40±3 versus 22±4 mm Hg, P <0.004, and 32±4 versus 15±4 mm Hg, P <0.01, respectively). All vasopressin animals survived 60 minutes, whereas no epinephrine pig had return of spontaneous circulation ( P <0.05). Conclusions —Repeated administration of vasopressin but only the first epinephrine dose given early and late during basic life support CPR maintained coronary perfusion pressure above the threshold that is needed for successful defibrillation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 175 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3