Assessment of Coronary Arterial Flow and Flow Reserve in Humans With Magnetic Resonance Imaging

Author:

Hundley W. Gregory1,Lange Richard A.1,Clarke Geoffrey D.1,Meshack Benjamin M.1,Payne Jerry1,Landau Charles1,McColl Roderick1,Sayad Dany E.1,Willett DuWayne L.1,Willard John E.1,Hillis L. David1,Peshock Ronald M.1

Affiliation:

1. From the Departments of Internal Medicine (Cardiovascular Division) (W.G.H., R.A.L., C.L., D.E.S., D.L.W., J.E.W., L.D.H., R.M.P.) and Radiology (G.D.C., J.P., R.M., R.M.P.), The University of Texas Southwestern Medical Center, Dallas.

Abstract

Background The noninvasive measurement of absolute epicardial coronary arterial flow and flow reserve would be useful in the evaluation of patients with coronary circulatory disorders. Phase-contrast magnetic resonance imaging (PC-MRI) has been used to measure coronary arterial flow in animals, but its accuracy in humans is unknown. Methods and Results Twelve subjects (7 men, 5 women; age, 44 to 67 years) underwent PC-MRI measurements of flow in the left anterior descending coronary artery or one of its diagonal branches at rest and after administration of adenosine (140 μg·kg −1 ·min −1 IV). Immediately thereafter, intracoronary Doppler velocity (IDV) and flow measurements were made during cardiac catheterization at rest and after intravenous administration of adenosine. For the 12 patients, the correlation between MRI and invasive measurements of coronary arterial flow and coronary arterial flow reserve was excellent: coronary flow MRI (mL/min)= 0.85×coronary flow IDV (mL/min)+17 (mL/min), r =.89, and coronary flow reserve MRI =0.79×coronary velocity reserve IDV +0.34, r =.89. For the range of coronary arterial flows (18 to 161 mL/min) measured by MRI, the limit of agreement between MRI and catheterization measurements of flow was −13±30 mL/min; for the range of coronary reserves (0.7 to 3.7) measured by MRI, the limit of agreement between the two techniques was 0.1±0.4. Conclusions Cine velocity-encoded PC-MRI can noninvasively measure absolute coronary arterial flow in the left anterior descending artery in humans. PC-MRI can detect pharmacologically induced changes in coronary arterial flow and can reliably distinguish between those subjects with normal and abnormal coronary artery flow reserve.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 155 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3