Flow Volume and Shunt Quantification in Pediatric Congenital Heart Disease by Real-Time Magnetic Resonance Velocity Mapping

Author:

Körperich Hermann1,Gieseke Jürgen1,Barth Peter1,Hoogeveen Romhild1,Esdorn Hermann1,Peterschröder Andreas1,Meyer Hans1,Beerbaum Philipp1

Affiliation:

1. From the Clinic for Congenital Heart Disease and Institute for Magnetic Resonance Imaging (H.K., P. Barth, H.E., A.P., H.M., P. Beerbaum), Heart- and Diabetescenter Northrhine-Westfalia, Ruhr-University of Bochum, Germany, and Philips Medical Systems (J.G., R.H.), Best, The Netherlands.

Abstract

Background— Flow quantification in real time by phase-contrast MRI (PC-MRI) may provide unique hemodynamic information in congenital heart disease, but available techniques have important limitations. We sought to validate a novel real-time magnetic resonance flow sequence in children. Methods and Results— In 14 pediatric patients (mean age 5.2±2.0 years) with cardiac left-to-right shunt, pulmonary (Q p ) and aortic (Q s ) flow rates were determined by nontriggered free-breathing real-time PC-MRI with single-shot echo-planar imaging combined with sensitivity encoding, which yielded 25 phase images per second at 2.7×2.7-mm in-plane resolution (field of view 30×34 cm 2 ). Over a 9.5-second period that included 2 to 5 respiratory cycles, 16.6±2.6 subsequent stroke volumes (range 13 to 22) were acquired in each vessel. Results were compared with conventional retrospectively ECG-gated PC-MRI. Mean Q p /Q s by conventional PC-MRI was 1.91±0.64, and it was 1.94±0.68 (mean±SD) by real-time PC-MRI. For blood flow rate through pulmonary artery and aorta, we found differences of 2% to 3% (Bland-Altman analysis), with lower limits of agreement of −11% to −13% (mean−2 SD) and upper limits of 18% to 19% (mean+2 SD), which demonstrated good agreement between both methods. Mean difference for Q p /Q s was 1%, with limits of agreement ranging between −18% and 22% (mean±2 SD). High repeatability but some flow overestimation was observed in vitro (pulsatile flow phantom) with real-time PC-MRI, whereas conventional PC-MRI was accurate. Beat-to-beat stroke-volume variation was 6.1±2.3% in vivo and 3.7±0.3% in vitro. Conclusions— Beat-to-beat quantification of pulmonary and aortic flows and hence left-to-right shunt within a few seconds is reliable by nontriggered real-time PC-MRI with echo-planar imaging and sensitivity encoding. Good spatial/temporal resolution and a large field of view may render the sequence valuable for multiple applications in congenital heart disease.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 87 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3