Determination of right atrial and right ventricular size by two-dimensional echocardiography.

Author:

Bommer W,Weinert L,Neumann A,Neef J,Mason D T,DeMaria A

Abstract

No data are available on determining right atrial and right ventricular size by two-dimensional echocardiography. We performed two-dimensional echocardiograms on eight human right-heart casts obtained at autopsy and on 50 patients who underwent complete left- and right-heart catheterization. Measurement of individual dimensions of the long and short axes of the right atrium and ventricle from right heart casts closely correlated with the volume of these structures as determined by water displacement. Further, individual dimensions by cross-sectional echo correlated well with actual casts dimensions. Subsequently, echocardiographic measurements of right atrial and ventricular long and short axes were obtained in the apical four-chambered view in a group of normals and compared with a group of patients with right ventricular volume overload states. Mean values for right atrial short-axis and long-axis measurements were greater in right ventricular volume overload patients than in normals: 6.5 +/- 0.3 vs 3.6 +/- 0.1 cm, and 6.0 +/- 0.3 vs 4.2 +/- 0.1 cm, respectively (both p less than 0.001). In addition, measurements of both individual dimensions as well as planed area of the right ventricle were greater in right ventricular volume overload patients than in normals: maximal short axis 6.1 +/- 0.3 vs 3.5 +/- 0.2 cm, mid-short axis 6.1 %/- 0.4 vs 2.8 +/- 0.2 cm, and area 40 +/- 2.6 vs 18 +/- 1.2 cm2 (all p less than 0.001). There were no differences in right ventricular long-axis measurement. Two-dimensional echocardiography provided better separation of normals from right ventricular volume overload patients than did M-mode techniques. Thus, two-dimensional echocardiography, with the apical four-chambered view, enables accurate visualization of the right atrium and ventricle in almost all patients. Futher, measurements of right atrial and right ventricular size by two-dimensional echocardiography readily distinguish normal patients from those with right ventricular volume overload.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 286 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3