Comparison of hirudin and heparin as adjuncts to streptokinase thrombolysis in a canine model of coronary thrombosis.

Author:

Rigel D F1,Olson R W1,Lappe R W1

Affiliation:

1. Research Department, CIBA-GEIGY Corp., Summit, N.J. 07901.

Abstract

Recombinant desulfatohirudin (HI), a potent and specific thrombin inhibitor, was compared with heparin (HE) as an adjunct to streptokinase thrombolysis. In pentobarbital-anesthetized dogs, an occlusive thrombus (whole blood+thrombin) was introduced into the left anterior descending coronary artery (LAD) with superimposed endothelial damage and distal high-grade stenosis. Intravenous infusion of saline (vehicle), HI (0.3 mg/kg followed by 0.3 mg/kg per hour, 1 mg/kg followed by 1 mg/kg per hour, or 2 mg/kg followed by 2 mg/kg per hour), or HE (60 units/kg followed by 40 units/kg per hour or 100 units/kg followed by 60 units/kg per hour) was initiated 15 minutes before streptokinase (750,000 units for 60 minutes) administration. Vessel patency was monitored for 180 minutes after streptokinase administration with a volume flow probe on the proximal LAD. In dogs treated with no adjunctive agent (saline control), none of the vessels were recanalized with streptokinase. Both HI and HE promoted reperfusion, inhibited reocclusion, and reduced the residual thrombus mass in a dose-dependent fashion. However, at comparable levels of therapeutic anticoagulation (activated partial thromboplastin time [APTT] = 1.5-2.0 times baseline) HI exhibited a higher incidence of reperfusion (eight of eight dogs [100%] versus one of eight dogs [12%]), a shorter time to reperfusion (33 +/- 6 versus 59 minutes), a longer duration of initial reperfusion (106 +/- 21 versus 10 minutes), and a smaller residual thrombus mass than did HE. Likewise, the slope of the relation between the APTT prolongation and the total reperfusion time ("anticoagulation/antithrombosis profile") was almost five times higher for the combined HI data than for the HE data. Our results indicate that HI is more effective than HE in enhancing and sustaining coronary recanalization with streptokinase at a HI dose that modestly prolongs coagulation time and does not alter bleeding times.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Physiology

Reference76 articles.

1. Heparin

2. Development of Hirudin as an Antithrombotic Agent

3. Comparative study of three recombinant hirudins with heparin in an experimental venous thrombosis model;Doutremepuich D;Haemostasis,1991

4. Antithrombotic effects of recombinant hirudin in different animal models;Just M;Haemostasis,1991

5. Hirudin interruption of heparin-resistant arterial thrombus formation in baboons;Kelly AB;Blood,1991

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3