Intraoperative Coronary Collateral Function in Patients With Coronary Occlusive Disease

Author:

GOLDSTEIN ROBERT E.1,STINSON EDWARD B.1,SCHERER JAMES L.1,SENINGEN RONALD P.1,GREHL TODD M.1,EPSTEIN STEPHEN E.1

Affiliation:

1. From the Cardiology Branch, NHLI, and the Department of Radiology, Clinical Center, National Institutes of Health, Bethesda, Maryland, and the Division of Cardiovascular Surgery, Stanford University School of Medicine, Stanford, California.

Abstract

To elucidate the direct influence of nitroglycerin on coronary collateral function in patients and to clarify the relation between angiographic appearance and functional performance of coronary collaterals, we measured retrograde flow and peripheral coronary pressure (PCP) before and after nitroglycerin in patients undergoing saphenous vein bypass. Measurements were made via the distally (but not proximally) attached vein graft while the coronary artery receiving the graft was totally occluded proximal to the site of graft attachment. Nitroglycerin (100 to 150 mcg bolus and 100 mcg/min) was infused into the ascending aorta in 29 patients. Baseline measurements revealed: aortic pressure mean 79 mm Hg, PCP 30 mm Hg, retrograde flow 2.7 ml/min, and collateral resistance 28.5 mm Hg/ml/min. Following nitroglycerin, mean aortic pressure decreased 18% but retrograde flow was not consistently changed; thus collateral resistance fell significantly (average 28%, P < 0.05). Similarly, collateral resistance fell (mean 50%) in eight individuals in whom aortic pressure changes were attenuated by altering systemic flow. If calculated as a fraction of aortic pressure, PCP increased 9.9% ( P < 0.02), a finding consistent with enhanced collateral flow. Our results suggest that nitroglycerin can diminish resistance to collateral flow despite severe multivessel involvement. Comparison of baseline data with preoperative angiography revealed a correlation between the size and extent of coronary collaterals and physiologic evidence of collateral function. Thus, angiographic appearance of coronary collaterals accurately predicts collateral function during bypass surgery.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference29 articles.

1. The Coronary Collateral Circulation

2. Local myocardial blood flow as indicated by the disappearance of NaI-131 from heart muscle: studies at rest, during exercise and following nitrite administration;J Pharmacol Exp Ther,1963

3. Measurements of normal and collateral coronary blood flow by close-arterial and intramyocardial injection of Krypton-85 and Xenon 133;Acta Physiol Scand,1966

4. Measurement of coronary flow in local areas of myocardium using xenon 133.

Cited by 214 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3