Ventricular Septal Defect Associated with Aortic Insufficiency

Author:

KAWASHIMA YASUNARU1,DANNO MICHIAKI1,SHIMIZU YUKIHIKO1,MATSUDA IKARU1,MIYAMOTO TAKESHI1,FUJITA TSUYOSHI1,KOZUKA TAKAHIRO1,MANABE HISAO1

Affiliation:

1. From the First Department of Surgery and the Department of Radiology, Osaka Universtiy Medical School, Osaka, Japan.

Abstract

Thirty-five consecutive patients with ventricular septal defect (VSD) associated with aortic insufficiency (AI) who underwent corrective surgery are presented. There were seven operative and three late deaths among the patients operated upon before 1968. No death, however, was encountered among the most recent 18 consecutive patients. The VSD was closed directly in 14 patients and with a Teflon patch in 21. The aortic valve was repaired in 16 patients, replaced in eight, and no interference was indicated in 11. They were classified from the surgical viewpoint according to the location of the VSD, the anatomic type of the right ventricular outflow tract, and the severity of the aortic herniation as follows: type Ia, supracristal VSD and AI without aortic cusp herniation; type lb, supracristal VSD and AI with aortic cusp herniation and conal muscular rim beneath the pulmonic valve; type Ic, supracristal VSD and AI with aortic cusp herniation without conal muscular rim beneath the pulmonic valve; type IIa, infracristal VSD and AI without aortic cusp herniation; type IIb, infracristal VSD and AI with aortic cusp herniation; type III, infracristal VSD and AI with infundibular pulmonic stenosis (PS); type IV, supracristal VSD and AI with infundibular PS. In type Ia and IIa, VSD was closed directly and the aortic valve was replaced. In most of type Ib, VSD was closed directly and no direct procedure was performed upon the aortic valve. In most of type Ic, VSD was closed with a Teflon patch and the aortic valve was repaired. In type IIb, VSD was closed with a Teflon patch and the procedure upon the aortic valve was not uniform. In type III, VSD was closed with a Teflon patch and the aortic valve was repaired in most of them. In type IV, VSD was closed with a Teflon patch and no direct procedure was performed upon the aortic valve. The basic policy for repair of this association of anomalies is selected according to the above mentioned anatomic classification.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 43 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Lesions with Normal Segmental Connections;Wilcox's Surgical Anatomy of the Heart;2024-04-30

2. Ventricular Septal Defect;Pediatric Cardiac Surgery;2023-02-03

3. Ventricular Septal Defects;Congenital Heart Disease;2022

4. Adult Supracristal Ventricular Septal Defect with Aortic Regurgitation: A Case Report;JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH;2021

5. Ventricular Septal Defect;Pediatric Cardiac Surgery;2013-02-28

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3