Characteristics and Outcomes of Patients Receiving New and Replacement Implantable Cardioverter-Defibrillators

Author:

Kramer Daniel B.1,Kennedy Kevin F.1,Noseworthy Peter A.1,Buxton Alfred E.1,Josephson Mark E.1,Normand Sharon-Lise1,Spertus John A.1,Zimetbaum Peter J.1,Reynolds Matthew R.1,Mitchell Susan L.1

Affiliation:

1. From the Beth Israel Deaconess Medical Center, Boston, MA (D.B.K., A.E.B., M.E.J., P.J.Z., M.R.R., S.L.M.); Harvard Medical School, Boston, MA (D.B.K., P.A.N., A.E.B., M.E.J., S.-L.N., P.J.Z., M.R.R., S.L.M.); Mid-America Heart Institute, Kansas City, MO (K.F.K., J.A.S.); Massachusetts General Hospital, Boston (P.A.N.); Hebrew SeniorLife Institute for Aging Research, Boston, MA (D.B.K., S.L.M.); and Harvard School of Public Health, Boston, MA (S.-L.N.).

Abstract

Background— Little is known about the clinical features, procedural risks, or survival of patients receiving replacement versus new implantable cardioverter-defibrillators (ICDs). Methods and Results— Entries in the National Cardiovascular Data Registry (NCDR) ICD Registry from 2005 through 2010 were eligible for inclusion (n=463 978). Baseline demographic data, clinical information, and procedural variables were compared between patients receiving new (n=359 993; 77.6%) and replacement (n=103 985; 22.4%) ICDs and entered into a propensity match model to determine adjusted survival rates. Patients receiving replacement ICDs were older (70.7 versus 67.5 years of age) and more likely to have atrial fibrillation (41.8% versus 31.4%; P <0.001) and ventricular tachycardia (60.5% versus 33.9%; P <0.001) compared with patients receiving new ICDs. Median battery life was only 4.6 years (25%–75% interquartile range, 3.7–5.8) for all replaced devices, 5.8 (25%–75% interquartile range, 4.2–7.5) for single-chamber, 5.1 (25%–75% interquartile range, 4.1–6.1) for dual-chamber, and 3.9 (25%–75% interquartile range, 3.2–4.6) years for biventricular devices. Patients receiving replacement ICDs had lower rates of index admission complications (0.9% versus 3.2%; P <0.001) but greater risk for death compared receiving patients receiving new ICDs in unadjusted analysis (hazard ratio, 1.18; 95% confidence interval, 1.16–1.20; P <0.0001) and after propensity-score matching (hazard ratio, 1.28; 95% confidence interval, 1.25–1.30; P <0.0001). Conclusions— Patients receiving replacement ICDs are older and at greater risk for death compared with those receiving initial ICD implants. The battery life of initial ICDs is shorter than previously reported.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3