Comparative Effectiveness of Wide Antral Versus Ostial Pulmonary Vein Isolation

Author:

Proietti Riccardo1,Santangeli Pasquale1,Di Biase Luigi1,Joza Jacqueline1,Bernier Martin Louis1,Wang Yang1,Sagone Antonio1,Viecca Maurizio1,Essebag Vidal1,Natale Andrea1

Affiliation:

1. From the Cardiology Department, Luigi Sacco Hospital, Milan, Italy (R.P., A.S., M.V.); Cardiac Electrophysiology Service, McGill University Health Center, Montreal, Canada (R.P., J.J., M.L.B., V.E.); Department of Cardiology, University of Pennsylvania, Philadelphia (P.S.); Cardiology Department, University of Foggia, Foggia, Italy (P.S., L.D.B.); Department of Biomedical Engineering, University of Texas, Austin (L.D.B., A.N.); Hôpital Sacre Cœur de Montréal, Montréal, Canada (V.E.); Texas Cardiac...

Abstract

Background— For the past decade, electric pulmonary vein isolation (PVI) has become a procedure implemented worldwide for the treatment of atrial fibrillation. Currently, 2 main approaches are used for PVI: ostial isolation of the PVs and wide antral PVI. The aims of this systematic review are to evaluate the relative merits of each technique with a pooled comparative analysis of efficacy and complications. Methods and Results— Studies were identified by searching electronic databases for studies on ostial versus antral PVI. Information was extracted from each included trial. Odds ratio was the primary measure of treatment effect or side effects. The proportion of patients with recurrences of atrial fibrillation or other atrial tachyarrhythmias was evaluated at the end of the follow-up periods in 12 trials, including 1183 patients. The recurrence rate of total supraventricular arrhythmias was significantly lower in wide antral than in segmental PVI group (odds ratio, 0.42; 95% confidence interval, 0.32–0.56; P <0.00001). Atrial fibrillation recurrence was significantly lower in the wide antral group (odds ratio, 0.33; 95% confidence interval, 0.24–0.46; P <0,00001). A trend toward a higher incidence of left atrial tachycardia occurrence in the wide antral circumferential ablation group was detected, which did not reach statistical significance (odds ratio, 1.53; 95% confidence interval, 0.88–2.69; P =0.13). Conclusions— Our primary finding is that PVI performed with a wide antral approach is more effective than ostial PVI in achieving freedom from total atrial tachyarrhythmia recurrence at long-term follow-up.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 110 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3