High-Resolution Mapping of Ventricular Scar

Author:

Tschabrunn Cory M.1,Roujol Sebastien1,Dorman Nicole C.1,Nezafat Reza1,Josephson Mark E.1,Anter Elad1

Affiliation:

1. From the Harvard-Thorndike Electrophysiology Institute (C.M.T., M.E.J., E.A.) and Cardiovascular Division, Department of Medicine (C.M.T., S.R., R.N., M.E.J., E.A.), Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA; and Biosense Webster, Johnson & Johnson, Diamond Bar, CA (N.C.D.).

Abstract

Background— Mapping resolution is influenced by electrode size and interelectrode spacing. The aims of this study were to establish normal electrogram criteria for 1-mm multielectrode-mapping catheters (Pentaray) in the ventricle and to compare its mapping resolution within scar to standard 3.5-mm catheters (Smart-Touch Thermocool). Methods and Results— Three healthy swine and 11 swine with healed myocardial infarction underwent sequential mapping of the left ventricle with both catheters. Bipolar voltage amplitude in healthy tissue was similar between 3.5- and 1-mm multielectrode catheters with a 5th percentile of 1.61 and 1.48 mV, respectively. In swine with healed infarction, the total area of low bipolar voltage amplitude (defined as <1.5 mV) was 22.5% smaller using 1-mm multielectrode catheters (21.7 versus 28.0 cm2; P =0.003). This was more evident in the area of dense scar (bipolar amplitude <0.5 mV) with a 47% smaller very low–voltage area identified using 1-mm electrode catheters (7.1 versus 15.2 cm 2 ; P =0.003). In this region, 1-mm multielectrode catheters recorded higher voltage amplitude (0.72±0.81 mV versus 0.30±0.12 mV; P <0.001). Importantly, 27% of these dense scar electrograms showed distinct triphasic electrograms when mapped using a 1-mm multielectrode catheter compared with fractionated multicomponent electrogram recorded with the 3.5-mm electrode catheter. In 8 mapped reentrant ventricular tachycardias, the circuits included regions of preserved myocardial tissue channels identified with 1-mm multielectrode catheters but not 3.5-mm electrode catheters. Pacing threshold within the area of low voltage was lower with 1-mm electrode catheters (0.9±1.3 mV versus 3.8±3.7 mV; P =0.001). Conclusions— Mapping with small closely spaced electrode catheters can improve mapping resolution within areas of low voltage.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 124 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Multipolar mapping in the management of different arrhythmias;Journal of Arrhythmology;2024-01-22

2. Multisize Electrode Field-of-View;JACC: Clinical Electrophysiology;2024-01

3. Catheter ablation of ventricular tachycardia: strategies to improve outcomes;Frontiers in Cardiovascular Medicine;2023-08-14

4. Endomyocardial substrate of ventricular arrhythmias in patients with autoimmune rheumatic diseases;Journal of Cardiovascular Electrophysiology;2023-08-09

5. Impact of filter configurations on bipolar EGMs: An optimal filter setting for identifying VT substrates;Journal of Cardiovascular Electrophysiology;2023-07-11

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3